Technical Specification
Voltage
Power Consumption
Temperature
Vacuum Pressure
Heating Element
Accessories
Certificate
Station Size (mm)
Weight (kgs)
Operating Instruction
Caution:Make sure that the four screws which are used to fasten
the Diaphragm pump are removed from the control system before
use. Otherwise serious damages may be caused to the user and
the system.
1. Place the desoldering iron gun in the holder separately. Then
connect the plug to the receptacle on the station and turn
clockwise to tighten the plug nut. Check that the power supply
is corresponding to the specification on the type plate and the
power switch is on the "OFF" position. Connect the control
unit to the power supply and switch on the power. Then a
self‐test is carried out in which all display elements are
switched on briefly. The electronic system then switches on
automatically to the set temperature and displays this value.
2. The display and temperature setting
Spare tip x 3 ( 0.8(on the gun)1.0/
1.3mm)
Cleaning tool x 3 (0.7/0.9/ 1.2mm)
Filter sponge x 4 (φ20.8x1 +φ16.8x3)
2
220~240V AC
140W
160°C ~ 480°C
600mm Hg
Ceramic Heater
CE, GS, RoHS
225 x 160 x 130
2.5