Medium Temperature, Top Mount, Solid Pull Door
Dimensional Drawings
Refrigerator Specifications
Specification
Compressor Mount
Temperature Range
Number of Doors
Door Construction
Hinge Type
Insulation
Wall Thickness
Capacity - Gross
Shipping Weight (Approx.)
Compressor BTUH/-10°F Evap.
Condenser Type
Evaporator Type
Refrigerant Type
Refrigerant Control
Amp Rating (80° Running)
Electrical Specs. (V / Hz / Ph)
NSF
UL Listed
Interior Finish
Exterior Finish
Compressor Make
Electrical Information
12
TOP MOUNT SOLID DOOR DRAWINGS & SPECIFICATIONS
1-Door
Top
32° to 55° (0° to 13°C)
1
Foam-In-Place
Camlift
Foam-in-Place Urethane
2 3/8"
3
27.3 ft.
440 lbs.
2126
Fin & Tube Forced Air
Fin & Tube Forced Air
R-404A
Expansion Valve
8.7
8.9 BT30RS
115 / 60 / 1
NSF7
Yes
Baked Enamel, Coved Corners
Baked Enamel
Tecumseh
15 Amp Service Cord
w/NEMA 5-15P Plug
2-Door
Top
32° to 55° (0° to 13°C)
2
Foam-In-Place
Camlift
Foam-in-Place Urethane
2 3/8"
3
49.1 ft.
604 lbs.
2126
Fin & Tube Forced Air
Fin & Tube Forced Air
R-404A
Expansion Valvee
8.7
8.9 BT50RS
115 / 60 / 1
NSF7
Yes
Baked Enamel, Coved Cornerss
Baked Enamel
Tecumseh
15 Amp Service Cord
w/NEMA 5-15P Plug