FURNACE SPECIFICATIONS
High Fire Input¹
High Fire Output¹
Low-Fire Steady-State Input¹
Low-Fire Steady-State Output¹
AFUE²
Temperature Rise Range (°F)
Vent Diameter³
No. of Burners
Circulator Blower
Available AC @ 0.5" ESP
Size (D x W)
Horsepower @ 1075 RPM
Speed
Filter Size (in²)
Permanent
Disposable
Electrical Data
Min. Circuit Ampacity⁴
Max. Overcurrent Device (amps)⁵
Shipping Weight (lbs)
¹ Natural Gas BTU/h
²
³
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and must be 2" or 3" diameter PVC.
⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
and noise issues.
may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility
clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
*CVC96
*CVC96
0403BNA
0603BNA
40,000
60,000
38,400
57,600
28,000
42,000
26,880
40,320
96
96
20 - 50
35 - 65
2" - 3"
2" - 3"
2
3
1.5 - 3
1.5 - 3
10" x 8"
11" x 8"
½
½
VS ECM
VS ECM
488
512
244
256
7.8
7.8
15
15
116
119
*CVC96
*CVC96
0804CNA
1005CNA
80,000
100,000
76,800
96,000
56,000
70,000
53,760
67,200
96
96
25 - 55
45 - 75
2" - 3"
2" - 3"
4
5
1.5 - 4
2 - 5
11" x 10"
11" x 10"
¾
1
VS ECM
VS ECM
853
711
427
356
10.6
14.4
15
20
143
145
*CVC96
1205DNA
120,000
115,200
84,000
80,640
96
35 - 65
2" - 3"
6
2 - 5
11" x 11"
1
VS ECM
1,024
512
14.4
20
158
5