Goodman GCVC960403BNAA Technical Manual page 13

96% gas furnace units
Table of Contents

Advertisement

BLOWER PERFORMANCE SPECIFICATIONS
*CVC961205DNA
Cooling Speeds
( @ .1" - .8" w.c. ESP)
High-Stage
Tap
Adjust
Minus 10%
Minus 5%
A
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
B
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
C
Normal
Plus 5%
Plus 10%
Minus 10%
Minus 5%
D
Normal
Plus 5%
Plus 10%
Notes
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
Low-Stage
CFM
CFM
769
486
811
513
854
540
897
567
939
594
1,011
783
1,067
827
1,123
870
1,179
914
1,235
957
1,259
900
1,329
950
1,399
1,000
1,469
1,050
1,539
1,100
1,624
1,112
1,714
1,173
1,804
1,235
1,894
1,297
1,984
1,359
*CVC961205DNA
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)
High-Stage
Tap
Adjust
CFM
Minus 10%
1,570
Minus 5%
1,657
A
Normal
1,744
Plus 5%
1,831
Plus 10%
1,918
Minus 10%
1,644
Minus 5%
1,736
B
Normal
1,827
Plus 5%
1,918
Plus 10%
2,010
Minus 10%
1,674
Minus 5%
1,767
C
Normal
1,860
Plus 5%
1,953
Plus 10%
2,046
Minus 10%
1,726
Minus 5%
1,822
D
Normal
1,918
Plus 5%
2,014
Plus 10%
2,110
Low-Stage
Rise
CFM
1,156
n/a
64
1,220
61
1,284
58
1,348
56
1,412
65
1,179
61
1,245
58
1,310
1,376
56
53
1,441
64
1,215
60
1,283
57
1,350
1,418
55
52
1,485
62
1,249
59
1,319
56
1,388
1,457
53
51
1,527
13