SPECIFICATIONS

4-1. SPECIFICATIONS
Model
Power source
Cooling capacity
(Nominal)
Power input
Current input
Heating capacity
(Nominal )
Power input
Current input
External finish
External dimension H x W x D
Net weight
Decoration panel
Model
External finish
Dimension
H x W x D
Net weight
Heat exchanger
FAN
Type x Quantity
External
static press.
Motor type
Motor output
Driving mechanism
Airflow rate
(Low-Mid2-
Mid1-High)
Noise level (Low-Mid2-Mid1-High)
(measured in anechoic room)
Insulation material
Air filter
Protection device
Refrigerant control device
Connectable outdoor unit
Liquid
Diameter of
(R410A)
refrigerant pipe
(R22, R407C)
Gas
(R410A)
(R22, R407C)
Field drain pipe size
Document
Standard
Accessory
attachment
Optional parts
Remark
Decoration panel **1
Air outlet shutter plate
High efficiency filter
element **2
Multi-function casement
Installation
Note :
1 Nominal cooling conditions
Indoor :
27:DB/19:WB (81°FDB/66°FWB)
Outdoor :
35:DB (95°FDB)
Pipe length :
7.5 m (24-9/16 ft)
Level difference :
0 m (0 ft)
* Nominal conditions 1, 3 are subject to JIS B8615-1.
* Due to continuing improvement, above specification may be subject to change without notice.
PLFY-P32VBM-E
kW
3.6
1
kcal / h
3,100
1
Btu / h
12,300
1
kcal / h
3,150
2
kW
0.03
A
0.22
kW
3
4.0
kcal / h
3
3,400
Btu / h
3
13,600
kW
0.02
A
0.14
mm
in.
kg (lb)
22 (49)
PLP-6BA
mm
in.
kg (lb)
Turbo fan x 1
Pa
0
mmH
O
0
2
kW
0.050
m
3
/ min
11 - 12 - 13 - 14
L / s
183 - 200 - 217 - 233
cfm
388 - 424 - 459 - 494
dB <A>
27 - 28 - 29 - 31
mm (in.)
[6.35 ([1/4)
[6.35 ([1/4)
[12.7 ([1/2)
mm (in.)
[12.7 ([1/2)
mm (in.)
PLP-6BA
PAC-SH51SP-E
PAC-SH59KF-E
PAC-SH53TM-E
**1.PLFY-P-VBM-E should use together with PLP-6BA.
*2.PAC-SH53TM-E is necessary to use with filter PAC-SH59KF-E.
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to
the Installation Manual.
2 Nominal cooling conditions
27:DB/19.5:WB (81°FDB/67°FWB)
35:DB (95°FDB)
5 m (16-3/8 ft)
0 m (0 ft)
PLFY-P40VBM-E
1-phase 220-240V 50Hz, 1-phase 220V 60Hz
4.5
3,900
15,400
4,000
0.04
0.29
5.0
4,300
17,100
0.03
0.22
Galvanized steel sheet
258 x 840 x 840
10-3/16 x 33-1/8 x 33-1/8
22 (49)
PLP-6BA
MUNSELL (6.4Y 8.9/0.4)
35 x 950 x 950
1-3/8 x 37-7/16 x 37-7/16
6 (13)
Cross fin (Aluminum fin and copper tube)
Turbo fan x 1
0
0
DC motor
0.050
Direct-drive
12 - 13 - 14 - 16
200 - 217 - 233 - 267
424 - 459 - 494 - 565
27 - 28 - 30 - 31
PP honeycomb
Fuse
LEV
R410A, R407C, R22 CITY MULTI
Flare
[6.35 ([1/4)
Flare
Flare
[6.35 ([1/4)
Flare
Flare
[12.7 ([1/2)
Flare
Flare
[12.7 ([1/2)
Flare
O.D. [32 (VP-25)
Installation Manual, Instruction Book
PLP-6BA
PAC-SH51SP-E
PAC-SH59KF-E
PAC-SH53TM-E
3 Nominal heating conditions
20:DB (68°FDB)
7:DB/6:WB (45°FDB/43°FWB)
7.5 m (24-9/16 ft)
0 m (0 ft)
8
PLFY-P50VBM-E
5.6
4,800
19,100
5,000
0.04
0.29
6.3
5,400
21,500
0.03
0.22
22 (49)
PLP-6BA
Turbo fan x 1
0
0
0.050
12 - 13 - 14 - 16
200 - 217 - 233 - 267
233 - 250 - 267 - 300
424 - 459 - 494 - 565
494 - 530 - 565 - 636
27 - 28 - 30 - 31
PS
[6.35 ([1/4)
Flare
[9.52 ([3/8)
Flare
[9.52 ([3/8)
[9.52 ([3/8)
[12.7 ([1/2)
Flare
[15.88 ([5/8)
[15.88 ([5/8)
Flare
[15.88 ([5/8)
PLP-6BA
PAC-SH51SP-E
PAC-SH59KF-E
PAC-SH53TM-E
*Above specification data is
subject to rounding variation.
PLFY-P63VBM-E
7.1
6,100
24,200
6,300
0.05
0.36
8.0
6,900
27,300
0.04
0.29
23 (51)
PLP-6BA
Turbo fan x 1
0
0
0.050
14 - 15 - 16 - 18
28 - 29 - 30 - 32
Flare
Flare
Flare
Flare
PLP-6BA
PAC-SH51SP-E
PAC-SH59KF-E
PAC-SH53TM-E
Unit converter
kcal/h = kW x 860
Btu/h = kW x 3,412
3
cfm
= m
/min x 35.31
lb
= kg / 0.4536

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents