Baxi MainEco Combi and System 24 - 28 - 35 / 18 - 24
Parameter Description
Shutdown input function
p36
Minimum gas pressure switch (GpS)
p37
Heat recovery unit (HRU)
p38
Flue gas damper running time
p39
Fault relay function
p40
Maintenance message
p41
Service operating hours
p42
Service burning hours
p43
Venting cycle
p44
(1) After commissioning, the boiler will operate once a week at 65°C for DHW.
02092014 - 7619497-02
Adjustment range
1 = Shutdown without frost-protection
2 = Shutdown with frost protection
3 = Lock-out with frost protection (Pump only)
0 = Not connected
1 = Connected
0 = Not connected
1 = Connected
0 to 255 seconds
0 = Operation signal
1 = Alarm signal
2 = External 3-way valve
Do not modify
Do not modify
Do not modify
0 = Stop
1 = Multiple speed pump
2 = Modulating pump
6. Commissioning
Factory setting
Combi
System
24
28
35
18
24
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
2
2
2
2
0
0
0
0
0
175 175 175 175 175
30
30
30
30
30
1
1
1
1
1
51