5-18 9020
Diagnostics
BASIC Peripheral System Functional Tests
Test Name
Pass/Fail Indicator
Description/Requirements
CS80
Hardware: 9020A, 9020B, or 9020C with any
CS/80 Disc Drive (and interface).
Test System Error number provided. Tests ability of HP disc drive to create a file, write
Refer to Chapter 10.
to a file. read from a file and purge a file. Data or
programs stored on the disc are not affected by
this test.
SS80
Test System Error number provided. This test is similar to the CS80 test, except that it
Refer to Chapter 10.
interacts with disc drives that do not support all
the features of CS/80 protocol (thus their identi-
fication by SS180, a subset of the command set
1980 protocol). SS/80 drives include: HP 9122,
9125. 9133, and 9134.
9895
Hardware' 9020A. 9020B, or 9020C with HP
9895 Flexible Disc Drive (and inter-
face)
Test System Error number provided Tests ability of HP 9895 flexible disc drive to
Refer to Chapter 10.
create a file, write to a file, read from a file and
purge a file. Data or programs stored on the disc
are not affected by this test.
8290x
Hardware: 9020A, 9020B. or 9020C with HP
8290x Flexible Disc Drive (and inter-
face).
Test System Error number provided. Tests ability of HP 8290x flexible disc drive to
Refer to Chapter 10.
create a file, write to a file, read from a file and
purge a file. Data or programs stored on the disc
are not affected by this test
TAPE
Test System Error number provided Test supported tape drives for file create. write.
Refer to Chapter 10.
read. and purge operations. Test destroys any
existing data on the tape.
9885
Test System Error number provided. Tests HP 9885 M/S flexible disc drive using a
Refer to Chapter 10.
dedicated GPIO interface. Except for HP-IB
address not applying. test operation is similar to
other tests. An initialized flexible disc is re-
quired for test.
9121
Test System Error number provided Tests HP 9121 disc drives. Test operation is simi-
Refer to Chapter 10.
lar to other flexible disc drive tests. An initialized
disc must be present in the drive 10. before
the test is executed.
SRM
Test System Error number provided. Tests SRM and interface by create a file. write,
Refer to Chapter 10.
read. and purge. Provides more information ab-
out current status during operation than most
tests in package.
HPIO
Test provides pass fail message upon Tests ability to write to and read from each 10
completion.
card. Does not perform comprehensive 1/0 card
test.
ASI
Hardware: 9020A. 9020B, or 9020C with HP
27128A Async. Serial Interface
Test provides pass fail message upon Tests the HP 27128A Asynchronous Serial Inter-
completion.
face card by writing to and reading from the
card. Provides a block of information describing
the card and its configuration
HPIB
Hardware 9020A. 9020B, or 9020C with HP
271lOA HP-IB Interface Card
T est provides pass fail message upon Tests the HP 271lOA HP-IB interface card by
completion
writing to and reading from the card. Provides a
block of information describing the card and its
configuration.
09020-90035. revY85