MAINS OPERATION & RESULTING TEMPERATURE
The following tables allow determining power supply and cabling requirements.
The power drawn from the mains network is converted into output power to feed the connected
loudspeaker systems and into heat. The difference between power consumption and dispensed power
is called power dissipation (Pd). The amount of heat resulting from power dissipation might remain
inside of a rack-shelf and needs to be diverted using appropriate measures. The following table is
meant as auxiliary means for calculating temperatures inside of a rack-shelf system/cabinet and the
ventilation efforts necessary.
The column „Pd" lists the leakage power in relation to different operational states. The column „BTU/hr"
lists the dispensed heat amount per hour.
CL800
idle
Max. Output Power @ 8Ω
Max. Output Power @ 4Ω
1/3 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
Normal Mode (-10dB) @ 4Ω
Rated Output Power (0dB) @ 4Ω
Alert (Alarm) Mode (-3dB) @ 4Ω
Max. Output Power @ 2Ω
1/8 Max. Output Power @ 2Ω
1/8 Max. Output Power @ 2Ω
1/8 Max. Output Power @ 2Ω
CL1200
idle
Max. Output Power @ 8Ω
Max. Output Power @ 4Ω
1/3 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
Normal Mode (-10dB) @ 4Ω
Rated Output Power (0dB) @ 4Ω
Alert (Alarm) Mode (-3dB) @ 4Ω
Max. Output Power @ 2Ω
1/8 Max. Output Power @ 2Ω
1/8 Max. Output Power @ 2Ω
1/8 Max. Output Power @ 2Ω
(1) Sine Modulation (1kHz)
(4) 1BTU = 1055.06J = 1055.06Ws
The following factors allow direct proportional calculation of the mains current Imain for different mains supply voltages:
100V = 2.3; 120V = 1.9; 220V = 1.05; 240V = 0.96
MAINS OPERATION & RESULTING TEMPERATURE
U
mains
[V]
230V
(1)
230V
(1)
230V
(1)
230V
(1)
230V
(2)
230V
(2),(5)
254V
(3)
230V
(3),(5)
254V
(1)
230V
(1)
230V
(1)
230V
(1)
230V
(1)
230V
(2)
230V
(3)
230V
U
mains
[V]
230V
(1)
230V
(1)
230V
(1)
230V
(1)
230V
(2)
230V
(2),(5)
254V
(3)
230V
(3),(5)
254V
(1)
230V
(1)
230V
(1)
230V
(1)
230V
(1)
230V
(2)
230V
(3)
230V
(2) VDE-Noise
(5) 10% Mains Over Voltage
I
P
mains
mains
[A]
[W]
0,42
50
4,4
735
7,2
1295
4,6
770
3,1
490
2,7
425
3,0
600
2,8
430
3,1
530
2,8
440
6,4
1130
4,9
820
11,2
2150
4,8
800
4,2
680
4,2
685
I
P
mains
mains
[A]
[W]
0,45
54
6,3
1070
10,4
1920
6,2
1065
2,6
400
2,9
455
3,1
500
2,9
450
3,2
550
2,4
365
9,6
1750
7,0
1220
16,1
3180
3,8
645
4,1
680
4,4
720
(3) pink-Noise EN60065 / 7. Edition
(6) Pd = Leakage Power
9
P
Pd
(6)
out
[W]
[W]
-
50
2 x 240
255
2 x 400
495
2 x 133
504
2 x 50
390
2 x 50
325
2 x 63
474
2 x 50
330
2 x 63
404
2 x 40
360
2 x 300
530
2 x150
520
2 x 600
950
2 x 75
650
2 x 75
530
2 x 75
535
P
Pd
(6)
out
[W]
[W]
-
54
2 x 350
370
2 x 600
720
2 x 200
665
2 x 75
250
2 x 75
305
2 x 93
314
2 x 75
300
2 x 93
364
2 x 60
245
2 x 500
750
2 x 250
720
2 x 900
1380
2 x 113
419
2 x 113
454
2 x 113
494
BTU/hr
(4)
170
870
1690
1720
1330
1110
1615
1125
1380
1230
1810
1775
3240
2220
1810
1825
BTU/hr
(4)
185
1260
2455
2270
855
1040
1070
1025
1240
835
2560
2455
4710
1430
1550
1685

Hide quick links: