ELECTRIC HEATER
NOT IDENTIFIED
ENTER SIZE:
NONE, 5,10,15 KW
PRESS +/- TO MAKE
SELECTION
BACK
Fig. 15 - - Selecting Electric Heater
Hydronic Heat Applications
The Evolution Control supports 2 types of Hydronic Heat
applications:
1. Hot water coil in combination with an FE fan coil and heat
pump, or hot water coil as sole heat source with an FE fan
coil.
2. Non- -zoned FE fan coil combined with radiant hot water
heat.
In either application, a Hydronic Heat kit should be installed in
place of an electric heater. See FE fan coil Product Data for
accessory part number. The system will identify that Hydonic Heat
has been installed during the initial commissioning process. The
system will treat the hot water coil as either auxiliary heat in a heat
pump application, or the sole heat source. Setup options for
Hydronic Heat applications are described in the Setup section of
this instruction.
Selecting Accessories
Once the indoor and outdoor equipment have been found or
entered, the following screens will appear allowing the Installer to
select the "AIR FILTER TYPE; HUMIDIFIER INSTALLED";
and "UV LIGHTS INSTALLED" (See Fig. 16). Use either Left or
Right Up/Down button to make appropriate selections in the
highlighted area on the display screen. Press right- -side button to
continue (or advance) to the next screen.
ACCESSORIES
ACCESSORIES
AIR FILTER TYPE:
HUMIDIFIER
EAC
EAC
INSTALLED?
MEDIA
MEDIA + EAC
PRESS +/- TO MAKE
PRESS +/- TO MAKE
SELECTION
SELECTION
CONTINUE
BACK
AIR FILTER MEDIA TYPE
HUMIDIFIER INSTALLED?
Fig. 16 - - Accessories —UV Lights
Air Filter Type
This accessory screen will appear first. The installer will need to
enter the type of filter (AIR FILTER, ELEC. AIR CLEANER , or
PURIFIER). See Table 1 and make a selection using Left or Right
Up/Down button, then press right- -side button to continue.
Table 1 – Filter Selection
INSTALLED FILTER
1--- in to 4--- in media
High voltage EAC
Evolution Air Purifier
Humidifier Installed
This will appear after the Air Filter Type screen. Select whether a
humidifier is installed on the system, YES or NO, then press
right- -side button to continue.
5 KW
CONTINUE
A03197
ACCESSORIES
U.V. LIGHTS
YES
INSTALLED?
YES
PRESS +/- TO MAKE
SELECTION
CONTINUE
BACK
CONTINUE
U.V. LIGHTS INSTALLED?
A03198
MENU
SELECTION
AIR FILTER
AIR CLEANER
AIR PURIFIER
UV Lights Installed
This screen will appear to select whether UV lights are installed on
the system, select YES or NO, then press right- -side button to
continue.
Equipment Summary
The "EQUIPMENT SUMMARY" screen will appear after
Accessories have been selected. This screen will give a summary of
all equipment automatically found or manually selected. If a wrong
selection was made, press left- -side button (BACK selection) to go
back to that particular screen and make changes. When everything
is OK, press right- -side button again to continue. (See Fig. 17.)
EQUIPMENT SUMMARY
FURNACE
355MAV042
AC
180ANA024
FILTER
EAC
HUMIDIFIER
YES
UV LIGHTS
YES
NO
YES
Fig. 17 - - Equipment Summary
The "SETUP COMPLETE! SAVE ALL SELECTIONS?" screen
will appear after Equipment Summary. To Save All Selections
press (YES) right- -side button. Pressing the left- -side button (NO
selection) will return to the Equipment Summary screen where
changes can be performed to any of the equipment selection
screens. After selecting YES, the initial power up sequence of the
new Evolution Control is complete.
Static Pressure Check
STATIC
PRESSURE
CHECK
PLEASE WAIT
Fig. 18 - - Static Pressure Check
This screen will appear after Setup is exited. The system will
perform a static pressure check. This process will take about 1 1/2
minutes to complete. When completed, a screen will appear
displaying the static pressure (in inches) across the equipment at
the expected highest delivered airflow. If the blower RPM is
greater than 1200, then a warning will appear, but equipment
operation and the TrueSenset dirty filter detection operation will
not be affected.
NOTE: The static pressure check occurs only at initial installation,
or when INSTALL is run in the INSTALL/SERVICE menu.

QUICK START

For first time installers, Quick Start will allow a quick start up of
the Evolution System before learning all the details of system
operation. However, for the best possible comfort and operation
refer to the Evolution Control Owner's Manual.
Set Day, Time & Desired Humidity
1. Open the door of the Evolution Control and press the BA-
SIC button.
2. Adjust the highlighted HOUR setting using the LEFT Up/
Down button.
3. Press SCROLL button (down) to highlight MINUTE.
4. Adjust the MINUTE setting using the LEFT Up/Down
button.
6
SETUP
COMPLETE!
SAVE
ALL SELECTIONS/
NO
YES
A07249
EXTERNAL STATIC
PRESSURE
MEASURED:
0.72 INCHES
AT 1200 CFM
CONTINUE >
A05000