TROUbLEShOOTING
The refrigerator does not cool properly
•
Burner jet clogged. Clean. See section "Maintenance &
Service",
•
Check level of refrigerator.
•
Restriction in air flow across cooling unit.
•
Heavy frost buildup on evaporator fins. Defrost.
•
Flue baffle not inserted properly in flue tube.
•
Improperly set thermostat. See paragraph on thermostat.
In hot weather the setting should be closer to "mAX" than
usual.
•
Burner dirty. Clean. See Section Maintenance & Service.
•
LP gas pressure low at burner. Set main regulator so pres-
sure does not drop below 11 inches water column at pressure
test port.
•
Burner not located properly under flue tube. Relocate.
•
Burner damaged. Replace.
•
Odors and fumes:
-
Dislocated burner.
-
Damaged burner.
-
Dirty flue tube.
385 13 71
120 VOLTS AC
3
N
L
2
mAINTENANCE & SERVICE
WIRING DIAGRAm
5
2
5
2
D
A
1
1
5N
5a
1
4L
4a
3
3a
2
2
2a
1
1a
B
C °
C
SPARE PARTS
The following list is a list of commonly used parts, which
will be available, if required, from your Dometic Service Cen-
ter.
Part No.
200 74 19-21/7
200 75 03-03/6
293 03 79-00/9
293 14 96-04/2
200 75 05-00/7
293 16 57-01/5
385 02 23-01/1
293 17 96-01/1
293 26 67-04/7
385 06 44-14/1
293 21 06-01/2
293 25 75-01/8
293 25 76-01/6
200 74 80-32/6
200 74 80-41/7
200 74 80-35/9
200 74 80-42/5
293 27 83-01/8
Contact an authorized service center for parts and repairs as
needed.
1
WHITE
2
BLACK
3
GREEN
4
RED
5
YELLOW/GREEN
A
HEATER
B
SWITCH
C
THERMOSTAT
D
TERMINAL BLOCK
E
SWITCH LIGHT
F
LIGHT
G
BATTERY BOX 6V
5
9
Description
Jet, no. 58
Burner, (with electrode)
Electrode
Thermocouple
Cover, (burner)
Safety valve
Thermostat
Piezo igniter
Baffle
Heater, 120V, 300W
Lamp cover
Door shelf
Door shelf, 3 pieces
Knob, thermostat, white
Knob, thermostat, grey
Knob, selector, white
Knob, selector, grey
Flap, base front
120 VOLTS
AC
5N
N
5a
4L
4a
L
A
3a
3
2
2a
1
1a
C
B
F
E
2
4
G