Indoor Unit; Delay On Timer And Off Timer - Panasonic CS-E15DKEW Service Manual

Hide thumbs Also See for CS-E15DKEW:
Table of Contents

Advertisement

CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE
2.2.

Indoor Unit

Automatic Operation Switch
• Press for < 5s to run Automatic Operation.
(Used when the remote control cannot be used.)
• Press continuously for 5s and < 8s to run
Forced Cooling Operation.
• Press continuously for 8s and < 11s to
run Forced Heating Operation.
• Press continuously for 11s and < 16s to
change different remote controlling
setting (4 type of transmission code).
• Press continuously for 16s or < 21s to
switch OFF / ON Remote Control
Receiving Sound or H14 Abnormality
Detection Mode.
Operation Indication Lamps (LED)
POWER
TIMER
QUIET
POWERFUL
(Green) ............ Lights up in Ionizer
SUPER ALLERU-BUSTER ....
(Blue)
(Green) ...... Lights up in operation,
blinks in Automatic
Operation Mode
judging, deice, On
Timer sampling and
Hot Start operation.
(Orange) .... Lights up in Timer
Setting.
Blinks in Self
Diagnosis Control.
(Orange) .... Lights up in Quiet
Mode Operation.
(Orange) ... Lights up when
Powerful Mode is
selected.
Mode Operation.
Blinks in Ionizer
error.
Lights up in
operation.
Four Operation Modes
• Automatic, Heating, Cooling and Soft Dry
Operation.
Automatic and 5 Manual Indoor
Fan Speeds
Automatic and 5 Manual Vertical
Airflow Directions
Automatic and 5 Manual Horizontal
Airflow Directions
Powerful Mode
• For quick cooling or heating.
Quiet Mode
• To provide quiet operation.
Ionizer Control
• Ionizer control for generate negative ion
in discharge air.

Delay ON Timer and OFF Timer

Automatic Restart Control
• Operation is restarted after power failure
at previous setting mode.
Microcomputer-controlled Room
Temperature Control
4