Shift Register 1 : BU4094BCFV (TX-RX Unit IC18)
Pin No.
Port
Port name
1
STRB
ES
Strobe
2
DATA
DAT
Data
3
CLK
CK
Clock
4
Q1
LEDR
Red LED. H : On, L : Off
5
Q2
LEDG
Green LED.
6
Q3
KEYBLT
Key backlight. H : On, L : Off
7
Q4
MMUTE
MIC mute. H : Unmute, L : Mute
8
VSS
GND.
9
QS
IC18 data output.
10
Q'S
NC
11
Q8
DTMPD
DTMF decode IC power down.
H : Power down, L : Busy
12
Q7
Not used.
13
Q6
5TC
TX power control. H : RX, L : TX
14
Q5
5RC
RX power control. H : TX, L : RX
15
OE
OE
Output enable.
16
VDC
5M
+5V.
VCO System : KCH31, KCH32 (TX-RX Unit IC14)
Circuit diagram
CV
MD
TA
SEMICONDUCTOR DATA
Function
H : On, L : Off
C2
L1
3
R2
2
R1
1
Q1
Q1 : 2SK1824
D1 : HVC350B
Q2 : 2SC4226(R25)
D2 : HVC202A
Q3 : 2SC5008
D3 : MA2S077
Shift Register 2 : BU4094BCFV (TX-RX Unit IC19)
Pin No.
Port
Port name
1
STRB
ES
2
DATA
DAT
3
CLK
CK
4
Q1
AM1
5
Q2
LOK
6
Q3
TA
7
Q4
8
VSS
9
QS
10
Q'S
11
Q8
SQ
12
Q7
CODE2
13
Q6
CODE1
14
Q5
OPT
15
OE
OE
16
VDC
5M
C8
Q2
Q3
C12
R4
R5
TK-480/481
Function
Strobe
Data
Clock
Audio mute 1. H : Unmute, L : Mute
Link complete (Programmable active H/L).
Talk around.
H : Off, L : On
NC
GND
NC
NC
External squelch (Programmable active H/L).
Option board data 2.
Option board data 1.
Option board control.
Please set option board type in the
KPG-49D.
H : On, L : Off
Auxiliary signal outut. Please set key
function in the KPG-49D (Program-
mable active H/L).
Output enable.
+5V.
4 OUT
C15
5 GND
6 5C
21