[L] Lens unit
(1) Remove the damp heater.
(2) Remove the shield bracket (2 screws).
(3) Remove the 5 screws, and disconnect the 2
connectors.
(4) Draw out the lens unit upwards.
Notes: 1: When replacing the lens unit, do not
touch the fixing screw (arrow in the figure:
8 points).
• Pay attention to the two screws (see above figure) on the rear side (see in the figure A.)
(Front side)
2: Also, when handling the unit, take suffi-
cient care not to hold the adjustment sec-
tion and the lens.
8070/6570/5570/4580 SCANNER
(Rear side)
A
7 - 24
Shield bracket
FG clamp