Key Parts Checking - Midea MSY-09HRDN1-QC8 Service Manual

Air conditioner dc inverter split wall-mounted type, r410a, 1ph, 220~240v, 50hz
Table of Contents

Advertisement

9.3 Checking for temperature sensors
Room temp.(T1) sensor,
Indoor coil temp.(T2) sensor,
Outdoor coil temp.(T3) sensor,
Outdoor ambient temp.(T4) sensor,
Compressor exhaust temp.(Te) sensor.
Measure the resistance value of each winding by using the multi-meter.
Some frequently-used R-T data for T1,T2,T3 and T4 sensor:
Temperature (℃)
Resistance Value
(KΩ)
Some frequently-used R-T data for Te sensor:
Temperature (℃)
Resistance Value (KΩ)
5
10
15
26.9
20.7
16.1
5
15
25
141.6
88
56.1
20
25
30
40
12.6
10
8
5.2
35
60
70
80
36.6
13.8
9.7
6.9
50
60
3.5
2.4
90
100
5
3.7
40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents