Component Testing Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires it.
Illustration
Timer 7 minute
2
4
3
1
Control
1
CN3
CN1
12
1
8
Fuse block /
Fuse
Filter board
L
L
N
N
Touch panel
LD510P
1000 WATT
10 PROGRAM PADS
3 COOKING STAGES
18
!
Component
Disconnect wire from terminals.
Measure resistance of the following
terminals:
Terminal 3 to terminal 4 (timer motor)......
Terminal 1 to terminal 2(timer switch) ......
CN1
Pin 1 (black) to Pin 3 (white) .......................
RY2 (Cook Relay)
Unplug oven and remove wire leads from
RY2 terminals. Connect ohm-meter leads
to terminals.
Plug oven into power supply ......................
Initiate cook cycle ......................................
NOTE: RY2 should cycle when using
RY3 (Fan Relay)
Unplug oven and remove wire leads from
RY3 terminals. Connect ohm-meter leads
to terminals.
Plug oven into power supply ......................
Initiate cook cycle ......................................
NOTE: Fan relay remains energized for 60
Disconnect wire from terminals.
Measure resistance of the following
terminals:
Verify fuse is good .....................................
Terminal L to L...........................................
Terminal N to N .........................................
Continuity is indicated as 100 Ω and below.
DEL10E
Each pad must be pressed to perform the
1000 WATT
following test.
10 PROGRAM PADS
0%
20%
50%
70%
QTY
2X
3 COOKING STAGES
16022150 Rev. 0
WARNING
Test
reduced power levels.
seconds following cook cycle.
1
2
3
4
5
6
7
8
9
10
11
Results
Approximately 22 KΩ
Timer OFF infinite Ω
Timer ON < 1 Ω
Line voltage input to control
transformer.
Infinite Ω
< 1 Ω
Power levels for Relay 2
Power
Cycles
Cycles
Level
On for:
Off for:
20%
6 sec
16 sec
40%
10 sec
12 sec
60%
14 sec
8 sec
80%
18 sec
4 sec
100%
22 sec
0 sec
Infinite Ω
< 1 Ω
< 1 Ω
< 1 Ω
< 1 Ω
Pad
Trace
Measurement
1
2 & 8
Continuity
2
3 & 8
Continuity
3
4 & 8
Continuity
4
5 & 8
Continuity
5
6 & 8
Continuity
6
7 & 8
Continuity
7
1 & 9
Continuity
8
2 & 9
Continuity
9
3 & 9
Continuity
0
1 & 8
Continuity
Hold
1 & 10
Continuity
Defrost
2 & 10
Continuity
Medium
3 & 10
Continuity
MED-HI
4 & 10
Continuity
Time Entry
5 & 10
Continuity
Stop/Reset
6 & 10
Continuity
Start
7 & 10
Continuity
X2
7 & 9
Continuity
©2003 Maytag Appliances Company