SECTION 5
5-1 PREPARATION
When adjusting IC-F24/F25/S, the optional CS-F14 ADJ
below) and OPC-478 (RS-232 type) or OPC-478U (USB type)
REQUIRED TEST EQUIPMENTS
EQUIPMENT
Output voltage
DC power supply
Current capacity
Frequency range
FM deviation meter
Measuring range
Frequency range
Frequency counter
Frequency accuracy : ±1 ppm or better
Sensitivity
Digital multimeter
Input impedance
Measuring range
RF power meter
Frequency range
(terminated type)
Impedance
SWR
S INAD m et er
Measuring range
SYSTEM REQUIREMENTS
®
®
• Microsoft
Windows
98/SE/ME/2000/XP
• RS232C/USB port
BEFORE STARTING SOFTWARE ADJUSTMENT
Clone adjustment freqencies, TX power, CTCSS frequency,
DTCS code and IF bandwidth (see
CONFIGULATION
on the next page) into the transceiver
using with the CS-F14
CLONING SOFTWARE
SOFTWARE ADJUSTMENTS. Otherwise, the transceiver
can not be adjusted.
CAUTION!:
BACK UP the originally programmed memory
data in the transceiver before programming
the adjustment frequencies.
When program the adjustment frequencies
into the transceiver, the transceiver's memory
data will be overwritten and lose original
memory data at the same time.
(JIG CABLE
To IC-F24/F25/S
[SP] jack
ADJUSTMENT PROCEDURES
GRADE AND RANGE
: 7.2 V DC
: 5 A or more
: DC–600 MHz
: 0 to ±10 kHz
: 0.1–600 MHz
: 100 mV or better
: 10 MΩ/V DC or better
: 1–10 W
: 100–600 MHz
: 50 Ω
: Less than 1.2 : 1
: 2 0 –2 0 k H z
ADJUSTMENT
before starting
3-conductor 3.5(d) mm plug
JIG cable
(Rev. 1.0 or later), JIG cable (see the illust
ADJUSTMENT SOFTWARE
are required.
CLONING CABLE
EQUIPMENT
Audio generator
Attenuator
Standard signal
generator (SSG)
DC voltmeter
Oscilloscope
AC millivoltmeter
STARTING SOFTWARE ADJUSTMENT
(1) Connect IC-F24/F25/S and PC with OPC-478/U
and JIG CABLE.
(2) Turn the transceiver power ON.
(3) Boot up Windows, and click the program group 'CS-F14 ADJ'
in the 'Programs' folder of the [Start] menu, then CS- F14
ADJ's window appears.
(4) Click 'Connect' on the CS-F14's window, then appears
IC-F14's up-to-date condition.
(5) Set or modify adjustment data as desired.
Microsoft and Windows are registered trademarks of
Microsoft Corporation in the U.S.A. and other countries.
( SP + )
(SP − )
(GND)
(CLONE)
5 - 1
GRADE AND RANGE
Frequency range
: 300–3000 Hz
Output level
: 1–500 mV
Power attenuation
: 20 or 30 dB
Capacity
: 10 W or more
Frequency range
: 100–600 MHz
Output level
: 0.1 µV–32 mV
(–127 to –17 dBm)
(As open circuit.)
Input impedance
: 50 kΩ/V DC or better
Frequency range
: DC–20 MHz
Measuring range
: 0.01–20 V
Measuring range
: 10 mV–10 V
OPC-478/U
Need help?
Do you have a question about the IC-F24 and is the answer not in the manual?
Questions and answers