2. Adjusting the control unit:
ON / OFF switch
ON / OFF
- At the system ON / OFF switch, switch the boiler first OFF
and then ON again. There must not be any fault present at the
boiler.
- Press the reset button (within the following 30 seconds) and
it hold down during the next steps.
- After 5 seconds, the illuminated signal ring indicates the
currently selected gas type (see table adjusting the gas type).
- Turn the heating water temperature selector towards the
required gas type and check the setting by means of the colour
of the illuminated signal ring (see table adjusting the gas type).
- The adjustment will only be activated when the reset button is
released.
- A successful conversion of the gas type is indicated by a triple
flashing (yellow/red) of the signal ring.
Gas type
Signal ring
Heating water temperature adjustment
Table: Adjusting the gas type
Check the nozzle pressure after converting