MODEL 34 (ZC) ZERO CLEARANCE INSTALLATION
The installation must conform with local codes or in the absence of local codes,
with National Fuel Gas Code, ANSI Z223.1/NFPA54.
This appliance may be installed in an After-Market
(Mobile) Home, where not prohibited by state or local codes.
* (After Market: Completion of sale, not for purpose of resale from manufacturer).
This appliance is only for use with the type of gas indicated on trating plate. This appliance is
not convertible for use with other gases.
NOTE: See "Producing Adequate Air For Combustion And Ventilation" page 35.
CHOOSING THE LOCATION FOR YOUR FIREPLACE:
The figure below shows some of many ways your fireplace may be installed. Consider traffic
pattern in your room and location of doors and windows. Moving air from ceiling fans, open
doors and hot air grills may cause flames to soot. If a disturbance is found that affects flames, it
must be eliminated by turning off ceiling fan, closing door or closing or moving hot air register.
A corner location may be best where space is limited.
Your fireplace weighs no more than some of your fine furniture. If fireplace is located near a
load bearing wall, additional supports to foundation will not be necessary. HEAVY FACINGS,
SUCH AS BRICK, STONE, ETC.,
SUPPORT.
NOTE: If this appliance is installed directly on carpeting, tile or other combustible mate-
rial, other than wood flooring, appliance shall be installed on a metal or wood
panel extending full width and depth of appliance.

GAS LINE

Gas supply line and electrical supply must be
installed before framing in the fireplace by a
licensed installer.
DRAFTS
Do not locate the fireplace in high traffic
areas or areas exposed to high drafts and
winds.
Locate the fireplace away from
furniture and draperies.
SECTION V
MAY REQUIRE ADDITIONAL FOUNDATION
CORNER
Page 30
*