8. Self Programming Mode (TK-270G only)
Write mode for frequency data and signalling etc. Mainly
used by the person maintaining the user equipment.
8.1 Self programming mode setting
Remove D17 from the TX-RX unit (Figure 3) (K models
only). Hold down the [LAMP]+[ ] switches and turn the
power switch on.
When the self programming mode is entered, [SELF]
appears on the display. The mode changes automatically
to Model Select Mode and "PORTABLE" is displayed in
about one second.
Note :
This mode (self programming mode) cannot be set when it
has been disabled with the FPU.
Flow Chart
Radio type
[2]
Radio Band & Channel Type
[2]
Frequency Version
[2]
[3]
Self programming mode
[MON]
Channel set mode
Function set mode
Note :
IF the radio type of TK-270G was temporally set to "Mobile"
for the cloning purposes, "UNPROG" is displayed (at User
Mode) when the TK-270G is turned on.
In this case, please set the radio type back to "Portable" at
Model Select Mode menu.
8-2. Channel Setting Mode
This is a mode for making channel settings with the panel
keys without using the FPU.
Pressing [MON] when "SELF" is displayed, sets Channel
Setting Mode.
Select an item set using [3] then change the selection with
the encoder.
The data displayed using [2] is stored in the memory and
then proceeds to the next item. Pressing [3] proceeds to
the next item without storing it in the memory.
Press [MON] to set the display to "SELF" and return to reset
(default) status.
REALIGNMENT
Portable
Mobile
[CH]
VHF 8CH
VHF 128CH
[CH]
VHF F1
VHF F2
[CH]
[CH]
[LAMP]
TK-260G/270G
Fig. 3
[CH]
UHF 8CH
UHF 128CH
[CH]
[CH]
[CH]
UHF F1
UHF F3
[CH]
[CH]
Cannot be
Cannot be
set when
set when
Portable is
Mobile is
select
select
No. Function Choices Display
Select
1-128
_1-_1._
Channel
_1-128._
Select
1-128
_1.-_1_
Group
128.-_1_
1 RX frequency Step 2.5kHz-1MHz STP_250 Display when an item is selected
STP_1000 or when a step is changed
Blank
————
100.0000-
R.100.0000 The rightmost dot indicates
550.0000MHz
2 Rx Signaling OFF
————
QT 67.0-250.3Hz
QT_67.0_ [
(EIA Mode)
QT_250.3_ [ ] : Normal/Inverse
QT 67.0-250.3Hz
QT_67.0*
(0.1Hz Step Mode) QT_250.3*
DQT 000-777 (Normal) DQT000N*
(1 Step Mode)
DQT777N*
DQT 023-754 (Normal) DQT023N
(Standard Table Mode) DQT754N
DQT 000-777 (Inverse) DQT000I*
(1 Step Mode)
DQT777I*
DQT 023-754 (Inverse) DQT023I
(Standard Table Mode) DQT754I
X57-587X
Compoent Side
D17
UHF F4
Remarks
[3] : Group selection/
Channel selection change
(about 0.5 seconds)
[
] Step change
VHF : 2.5, 5.0,6.25,7.5kHz,1MHz,Step
[LAMP] : Freq On/Blank switching
50Hz digit (On=5; Off=0).
[LAMP] : Off/QT/DQT switching
] : Mode switching
switching