Kenwood TK-260G Service Manual page 12

Kenwood two-way radio - two way radio user manual
Hide thumbs Also See for TK-260G:
Table of Contents

Advertisement

TK-260G/270G
No. Function Choices Display
3 TX frequency Step 2.5kHz-1MHz STP_250
Blank
100.0000-
550.0000MHz
4 TX Signaling
5 Option Signaling OFF
DTMF
2-TONE
6 ID
000-
9999999999
Blank
7 Busy Channel NO
Lockout
Type 1
Type 2
8 Beat shift No
Yes
9 RF Power High Power PWR_H___
Low Power PWR_L___
10 Wide/Narrow Wide
Narrow
11 Scan
DELETE
Delete/ADD ADD
12 Priority
No
Channel
Yes
13 Home Channel No
Yes
14 Compander No
Yes
15 PTT ID
OFF
Begin of TX P.ID_1
End of TX P.ID_2
Both
16 Begin of
000-
TX ID
9999999999999999
Blank
17 END of
000-
TX ID
9999999999999999
Blank
12
REALIGNMENT
Remarks
Same as RX frequency.
STP_1000
————
T.100.0000
Same as RX signaling.
NONE____
Default
DTMF____
2TONE___
___ID___
Display when an item is selected
(about 0.5 seconds)
12345678 Display of the current setting
(If it is 8 or more digits, scroll it.)
——987 Display when a code is input
(Input it with DTMF key.)
————
[LAMP] : Data clear
BCL_NO__
Default
BCL_1___
BCL_YES for K type
BCL_2___
N/A for K type
SHFT_NO_
Default
SHFT_YES
Default
WIDE____
NARROW__
SCAN_DEL Not used for TK-260G
SCAN_ADD
Default
P.CH_NO__ Not used when (Scan) Priority is not Fixed.
P.CH_YES_
H.CH_NO__ Not used when Home Channel is
H.CH_YES_ not set in Key Assignment.
COMP_NO_ Not used when Wide is selected.
COMP_YES
P.ID_OFF
P.ID_3
_BOT_ID_
Not valid if Dial ID =Disable and
PTT ID=OFF, or EOT is set.
Display when an item is selected
(about 0.5 seconds)
12345678
Display of the current setting
(If it is 8 or more digits, scroll it.)
——987
Display when a code is input
(Input it with DTMF key.)
————
[LAMP] : Data clear
_EOT_ID_
Not valid if Dial ID =Disable and
PTT ID=OFF, or EOT is set.
Display when an item is selected
(about 0.5 seconds)
12345678
Display of the current setting
(If it is 8 or more digits, scroll it.)
——987
Display when a code is input
(Input it with DTMF key.)
————
[LAMP] : Data clear
Flow Chart
Channel Setting Mode
Self programming mode
[MON]
[MON]
Channel set mode
[2]
[MON]
RX frequency
[LAMP]
[2]/[3]
[MON]
RX signaling
[LAMP]
[2]/[3]
[MON]
TX freguency
[LAMP]
[2]/[3]
[MON]
TX signaling
[LAMP]
[2]/[3]
[MON]
option signaling
[2]/[3]
[MON]
ID
[LAMP]
[2]/[3]
[MON]
Busy channel lockout
[2]/[3]
[MON]
Best Shift yes/no
[2]/[3]
[MON]
RF Power High/Low
[2]/[3]
[MON]
Wide/Narrow
[2]/[3]
[MON]
Scan delete/add
[2]/[3]
[MON]
Priority channel
Not used when (Scan) Priority is not Fixed.
[2]/[3]
[MON]
Not used when Home Channel is not set in key Assignment.
Home channel
[2]/[3]
[MON]
Compander yes/no
Not used when Wide is selected.
[2]/[3]
[MON]
PTT ID
[2]/[3]
[MON]
Begin of TX ID
[LAMP]
[2]/[3]
[MON]
End of TX ID
[LAMP]
[2]/[3]
Channel selection
Group selection
[3]
OFF
[LAMP]
OFF
QT
DQT N
[ ]
[LAMP]
[LAMP]
OFF
[LAMP]
OFF
QT
DQT N
[ ]
[LAMP]
[LAMP]
Data clear
Not valid if Dial ID=Disable
Data clear
and PTT ID=off, or EOT is set.
Not valid if Dial ID=Disable
Data clear
and PTT ID=off, or BOT is set.
DQT I
DQT I

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: