1.4 IGNITION SYSTEM WIRING

• This gas heater is equipped with an electronic ignition
system which operates on a 6 volt system.
• This appliance requires 240 VAC to be wired to the
factory installed junction box. Check factory installed
power cord for damage before use.
WARNING
Shock hazard.
• Replace damaged wire with type 105º C
rated wire.
• Wire must have high temperature
insulation.
PILOT
Figure 41. Electronic Ignition Wiring Diagram
24
IGNITION MODULE
6VDC
BATTERY PORT
ON/OFF
SWITCH
GAS LINE
CONNECTED TO
BACK OF VALVE
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08
Label all wires prior to disconnection when servicing con-
trols. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
FLAME SPARKER/
SENSOR
VALVE
REMOTE
CONTROL
ANT.
WALL SWITCH
IGNITION
MODULE
GROUND
NEUTRAL
THERMOCOUPLE
BLOCK
(CONNECTED TO
BACK OF VALVE)