Specification – C-Stat 11-B | C-Stat 17-B
Power Supply
Contact type
Wiring configuration
Contact voltage rating
Contact current rating
Temperature differential
Temperature accuracy
Standards
Dimensions (WxHxD)
Weight
Enclosure
Ingress protection
Pollution degree
Insulation class
Software class
Control type
Temperature range
2 x AA Batteries
Micro-disconnection
Voltage free c/o contacts (SPDT)
230V ac 50Hz (30V dc)
8A (1A inductive)
0.5°C
+/- 0.5°C to 21°C
BS EN 60730-2-9
120mm x 100mm x 26.5mm
0.3kg (approx)
Flame retardant thermoplastic
IP30
Degree 2
Class II (Double Insulated)
Class A
Type 2B
0°C to 40°C