The Horstmann Electronic 7 is an advanced water heating control, which can be
programmed to take advantage of cheap night-rate electricity, so that there is a tank
of hot water available for the morning.
INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A
SUITABLY QUALIFIED PERSON AND IN ACCORDANCE WITH THE CURRENT
EDITION OF THE IET WIRING REGULATIONS.
WARNING : ISOLATE MAINS SUPPLY. BEFORE COMMENCING INSTALLATION
ENSURE THE UNIT IS PROPERLY EARTHED.
The Electronic 7 is supplied with its own surface mounting box, which can also be
mounted over a single or double gang flush wall box. It should NOT be mounted on
an unearthed metal surface. Means of disconnection from the supply having at least
3mm contact separation in both poles must be incorporated in the fixed wiring.
Horstmann recommends a separate fused circuit from the consumer unit (24 Hour
supply) protected by a 15 amp HRC fuse or, preferably, a 16 amp MCB. In some
cases immersion heater failure can damage the ELECTRONIC 7. Installation of a
100 mA RCD will provide additional protection for the unit. If the ELECTRONIC 7 is
to be connected to a ring main then the spur feeding the controller should be
protected in the same way.
Electronic 7
Installation Instructions
1

Advertisement

Table of Contents
loading

Summary of Contents for Horstmann electronic 7

  • Page 1 WARNING : ISOLATE MAINS SUPPLY. BEFORE COMMENCING INSTALLATION ENSURE THE UNIT IS PROPERLY EARTHED. The Electronic 7 is supplied with its own surface mounting box, which can also be mounted over a single or double gang flush wall box. It should NOT be mounted on an unearthed metal surface.
  • Page 2 Mounting The Electronic 7 should be removed from the mounting box by unscrewing the 2 captive screws securing the unit. Conduit Box Mounting Use either holes marked 'A' in Fig.1 to secure to a single gang box, or the two holes marked 'C' for a double gang box.
  • Page 3 On installation the installer needs to select whether the Electronic 7 will switch at GMT times throughout the year or whether the timings need to alter as the...
  • Page 4 Tariff Timeswitch the commissioning switch should be set to GMT ONLY. Time Display The Electronic 7 is fitted with an automatic clock that is pre-set on manufacture and should not normally require any adjustments by the user. The clock will automatically adjust the time to Summertime (BST) or Wintertime (GMT) as appropriate and this setting is always shown on the clock display.
  • Page 5 Setting Time of Day Adjust the hour Once you are by pressing happy with the The minutes Press the green the white time selected, will now flash. “SET” button “MINUS” or press the blue To adjust the until the “PLUS” “SELECT”...
  • Page 6 Default Time Settings Default Times 1st ON 1st OFF 2nd ON 2nd OFF 3rd ON 3rd OFF 2:15am 7:15am 12:00pm 12:00am 12:00am 12:00pm After re-setting the unit the off-peak heating times will revert back to the default factory settings, these are shown above, however if you wish to change these times please proceed as instructed in the SETTING OFF-PEAK HEATINGS PERIODS part of this manual on page 5.
  • Page 7 Specification Electrical Purpose of Control Electronic Immersion Heater Control for E7 Tariffs Contact Rating 13A Amp 230V AC (Suitable for Emmersion Heaters up to 3kW) Contact Type Micro-disconnection Switch Type Rocker switch, double-pole micro-disconnection Supply 230V AC 50Hz only Protection Class I Control Action Type 1B,R...
  • Page 8 South Bristol Business Park, Roman Farm Road, Bristol BS4 1UP t: +44 117 978 8700 e: sales@horstmann.co.uk www.horstmann.co.uk Part Number P83080 Issue 3...

Table of Contents