Battery Powered Programmable
Room Thermostat
Programmable room thermostats are widely recognised as one
of the best ways in which to control central heating. Horstmann
C-Stat programmable room thermostats have a large display
and intuitive user interface, making them easy to set up and use.
C-Stat uses a sophisticated time proportional integral (TPI)
algorithm for accurate temperature control and energy
efficiency. Being battery powered, these models are suitable for
replacing most existing room thermostats.
Installation and connection should only be carried out by a
suitable qualified person and in accordance with the edition of
the IEE wiring regulation.
Warning: Isolate mains supply before commencing installation.
1

Advertisement

loading

Summary of Contents for Horstmann C-Stat 11-B

  • Page 1: Installation Instructions

    Room Thermostat Programmable room thermostats are widely recognised as one of the best ways in which to control central heating. Horstmann C-Stat programmable room thermostats have a large display and intuitive user interface, making them easy to set up and use.
  • Page 2 Positioning the C-Stat programmable room thermostat The C-Stat should be mounted on an internal wall approximately 1.5 metres from floor level and should be in a position away from draughts, direct heat and sunlight. Ensure that there will be enough space to allow access to the two retaining screws located at the base of the wall plate 1.5m...
  • Page 3 Fitting the wall plate To remove the wall plate from the C-Stat undo the two retaining screws located on the underside, the wall plate should now be easily removed. Once the wall plate has been removed from the packaging please ensure the C-Stat is resealed to prevent damage from dust, debris etc.
  • Page 4 Wiring Box Mounting The C-Stat wall plate may be fitted directly on to a single gang steel flush wiring box complying with BS4662, using two M3.5 screws. The C-stat is suitable for mounting on a flat surface only; it must not be positioned on an unearthed metal surface. Electrical Connections All necessary electrical connections should now be made.
  • Page 5 C-Stat Mains Supply Remove link if Fitted E N L COMBINATION BOILER TERMINALS C-Stat controlling typical combination boiler installation. For precise termination connection information please refer to the boiler manufactures instructions CENTRAL Programmer WATER HEATING C-Stat MAINS SUPPLY ROOM STAT STAT MAINS SUPPLY...
  • Page 6 Programmer CENTRAL WATER HEATING MAINS C-Stat SUPPLY STAT CALL CALL PUMP & BOILER C-Stat replacing a conventional room thermostat on a fully pumped system with an existing programmer and 3 port mid-position valve. Programmer CENTRAL WATER HEATING MAINS C-Stat SUPPLY STAT CALL CALL...
  • Page 7 All wiring diagrams are schematic and should be used for guidance only. INSTALLATION AND CONNECTION OF THE C-STAT MUST BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON. WARNING: ISOLATE MAINS SUPPLY BEFORE COMMENCING INSTALLATION TPI Temperature control software Thermostats using TPI (Time Proportional Integral) control algorithms will reduce the temperature swing that normally occurs when using traditional bellows or thermally operated thermostats.
  • Page 8 Fitting the C-Stat to the wall plate Fit the 2 x AA batteries provided under the hinged battery cover on the front of the unit. Ensure they are fitted correctly as indicated by the terminal markings in the battery compartment. Complete the installation by swinging the C-Stat into position by engaging the lugs at the top of the wall plate before pushing it firmly home into its plug-in terminal block.
  • Page 9: Installer Settings

    Installer Settings There are a number of 'Installer Settings' that should be set on installation. These can be found under the 'SET UP MENU' on page 15 of the user instructions. Clock Format AM/PM or 24 Hour clock display - Default setting AM/PM Daylight saving On or Off - Default setting ON for UK Market...
  • Page 10 Resetting the thermostat Electronic equipment can in some circumstances be affected by electrical interference. If the display becomes frozen or scrambled simply press both the BACK and ENTER button simultaneously. BACK ENTER...
  • Page 11 Specification – C-Stat 11-B | C-Stat 17-B Power Supply 2 x AA Batteries Contact type Micro-disconnection Wiring configuration Voltage free c/o contacts (SPDT) Contact voltage rating 230V ac 50Hz (30V dc) Contact current rating 8A (1A inductive) Temperature differential 0.5°C Temperature accuracy +/- 0.5°C to 21°C...
  • Page 12 Secure Controls (UK) Limited South Bristol Business Park, Roman Farm Road, Bristol BS4 1UP E-mail: sales@horstmann.co.uk Web site: www.horstmann.co.uk Part Number P84872 Issue 1...