ATTACHING COAX FOR PR- MODELS
STEP 4. Be sure to unfold tetrapole ele-
ments away from boom. Loosen wing nuts
on downlead connections. Attach match-
ing transformer ends to the studs between
the washers and tighten wing nuts. See Fig-
ure 8.
ATTACHING COAX FOR MODEL
HD7210P ONLY
STEP 4. Attach the 75 ohm coaxial down-
lead to the housing. Slide weather boot over
the boot collar. See Figure 9.
ATTACHING ANTENNA TO MAST
Loosen U-bolt nuts. Slide U-bolt over mast.
Point small end of antenna toward stations
and tighten securely. See Figure 10.
Install a second U-bolt for antennas with
multiple booms. The 75 ohm coaxial cable
downlead may be secured to mast by tap-
ing or by using plastic wire ties.
HOW TO PROVIDE
LIGHTNING PROTECTION
FOR TV ANTENNA AND SET
Step 1. Mount the grounding block as
close as possible to where the 75 ohm
coaxial cable downlead enters the house.
See Figure 11.
Step 2. The ground wires for both the mast
and the downlead should be copper or
aluminum wire, number eight (8) or larger.
See Figure 11.
Step 3. The downlead wire from the
antenna to the grounding block and the
mast ground wire should be secured to
the house spaced from four (4) to six (6)
feet apart. See Figure 11.
NOTE: In the case of a "ground up" an-
tenna installation, it may not be neces-
sary to ground the mast if the mast ex-
tends four or more feet into the earth.
Consult a TV serviceman for the proper
depth in your location.
Printed in U.S.A. © Winegard Company 2003 1450172 Rev. 7/04
Fig. 8
ATTACH DOWNLEAD/
MATCHING TRANSFORMER HERE
Fig. 9
MAST CLAMP
Fig. 10
HEX NUT
MAST CLAMP
INSERT
U-BOLT
MASTING
Example of antenna grounding as per
National Electrical Code, ANSI/NFPA 70
Fig. 11
Antenna Lead
In Wire
Ground
Clamp
Electric
Antenna
Service
Discharge Unit
Equipment
(NEC Section 810-20)
Grounding Conductors
(NEC Section 810-21)
Ground
Clamps
Power Service Grounding
Electrode System
(NEC Art 250, Part H)
NEC - National Electrical Code
High Definition (HD)
Platinum Antennas
INSTRUCTIONS
VHF/UHF MODELS
HD7210P, PR-5646, PR-7000, PR-7005, PR-7010, PR-7013,
PR-7015, PR-7032, PR-7037, PR-7042 & PR-7052
VHF ONLY
PR-5030, YA-1026, YA-1713, YA-6260 & YA-6713
INSTALLATION OF THIS ANTENNA NEAR POWER LINES
IS DANGEROUS. FOR YOUR SAFETY, FOLLOW THE INSTAL-
LATION INSTRUCTIONS.
90 DAY LIMITED WARRANTY
Winegard Company warrants this Winegard product against any defects in materials or workmanship
within 90 (ninety) days from date of purchase. No warranty claim will be honored unless at the time the claim
is made, you present proof of purchase to an authorized Winegard dealer (if unknown, please contact
Winegard Company, 3000 Kirkwood Street, Burlington, IA 52601-2000, Telephone 319-754-0600).
Winegard Company (at its option) will either repair or replace the defective product at no charge to you.
This warranty covers parts, but does not cover any costs incurred in removal, shipping or reinstallation of
the product. This limited warranty does not apply if the product is damaged, deteriorates, malfunctions or fails
from: misuse, improper installation, abuse, neglect, accident, tampering, modification of the product as
originally manufactured by Winegard, usage not in accordance with product instructions or acts of nature such
as damage caused by wind, lightning, ice or corrosive environments such as salt spray and acid rain.
The 90 Day Warranty is provided on the condition that the equipment is properly delivered with all
handling and freight charges prepaid to your Winegard dealer for return to our factory for repair or
replacement. Winegard dealers will arrange for the replacement or repair and return to you without charge
the product which failed due to defective material or workmanship.
WINEGARD COMPANY WILL NOT ASSUME ANY LIABILITIES FOR ANY OTHER WARRANTIES,
EXPRESS OR IMPLIED, MADE BY ANY OTHER PERSON.
ALL OTHER WARRANTIES WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING WAR-
RANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY ARE LIMITED TO
THE 90-DAY PERIOD OF THIS WARRANTY.
The foregoing shall be the sole and exclusive remedy of any person, whether in contract, tort or
otherwise, and Winegard shall not be liable for incidental or consequential damage or commercial loss, or
from any other loss or damage except as set forth above.
Some states do not allow limitations on how long an implied warranty lasts, or the exclusion of limitation
of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state
to state.
Winegard Company • 3000 Kirkwood Street • Burlington, IA 52601-2000
WARNING

Advertisement

loading

Summary of Contents for Winegard HD7210P

  • Page 1 Winegard Company, 3000 Kirkwood Street, Burlington, IA 52601-2000, Telephone 319-754-0600). See Figure 11. Winegard Company (at its option) will either repair or replace the defective product at no charge to you. This warranty covers parts, but does not cover any costs incurred in removal, shipping or reinstallation of the product.
  • Page 2 Fig. 5 FOR MODELS WITH REFLECTOR FOR MODELS WITH BOOM BRACES BOOM Fig. 1 BOOMS INSTALLED IN FACTORY BRACE STEP 1. Assemble antenna using previ- REFLECTOR STEP 1. Remove antenna from carton and ous steps. Lay boom brace on top of an- BOOM unfold elements on reflector booms until tenna with U-bolts on same side.

This manual is also suitable for:

Pr-5646Pr-7000Pr-7005Pr-7010Pr-7013Pr-7015 ... Show all