Download Print this page
AirSep VisionAire 2 Patient Manual

AirSep VisionAire 2 Patient Manual

Oxygen concentrator
Hide thumbs Also See for VisionAire 2:

Advertisement

Quick Links

VisionAire
2
and
VisionAire
3
Oxygen Concentrator
Patient Manual
AirSep Corporation • 401 Creekside Drive • Buffalo, New York 14228-2085 USA
Telephone: (716) 691-0202 • 24-Hour Fax (716) 691-4141

Advertisement

loading

Summary of Contents for AirSep VisionAire 2

  • Page 1 ™ VisionAire ™ VisionAire Oxygen Concentrator Patient Manual AirSep Corporation • 401 Creekside Drive • Buffalo, New York 14228-2085 USA Telephone: (716) 691-0202 • 24-Hour Fax (716) 691-4141...
  • Page 2 [Read the Important Safety Rules section before operating this equipment.] DO NOT OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND UNDERSTANDING THIS MANUAL. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS AND INSTRUCTIONS, CONTACT YOUR EQUIPMENT PROVIDER BEFORE ATTEMPTING TO USE THIS EQUIPMEN; OTHER INJURY OR DAMAGE COULD OCCUR.
  • Page 3: Table Of Contents

    [Read the Important Safety Rules section before operating this equipment.] Table of Contents: Important Safety Rules Page 1-4 Section 1 Introduction Page 6 Why Your Physician Prescribed Oxygen Page 6 What is an Oxygen Concentrator? Page 6 Operator Profile Page 7 Section 2 Concentrator Components Page 8...
  • Page 4 [Read the Important Safety Rules section before operating this equipment.] Important Safety Rules Carefully review and familiarize yourself with the following important safety information about the VisionAire™ 2 and VisionAire™ 3 Oxygen Concentrator. “No Smoking – Oxygen in Use” signs must be prominently displayed in the home, or where oxygen is in use.
  • Page 5 [Read the Important Safety Rules section before operating this equipment.] Electrical shock hazard. Turn Off the unit and disconnect the power cord from the electric outlet before you clean the unit to prevent accidental electrical shock and burn hazard. Only your Equipment Provider or a qualified service technician should remove the covers or service the unit.
  • Page 6 [Read the Important Safety Rules section before operating this equipment.] Cet appareil produit de l’oxygène à concentration élevée, favorisant une combustion rapide. Ne pas permettre de fumer ou des flammes nues dans même chambre: (1) cet appareil ou (2) tout accessoire contenant de l’oxygène.
  • Page 7 [Read the Important Safety Rules section before operating this equipment.] The Manufacturer recommends an alternate source of supplemental oxygen in the event of a power outage, alarm condition, or mechanical failure. Consult your physician or Equipment Provider for the type of reserve system required. It is very important to select only the prescribed level of oxygen.
  • Page 8 [Read the Important Safety Rules section before operating this equipment.] The use of some oxygen administration accessories not specified for use with this oxygen concentrator may impair its performance. Recommended accessories are referenced within this manual. To Equipment Provider: The following oxygen administration accessories are recommended for use with the Oxygen Concentrator •...
  • Page 9 The air we breathe contains approximately 21% oxygen, 78% nitrogen, and 1% other gases. In the VisionAire 2 or VisionAire 3 unit, room air passes through a regenerative adsorbent material called molecular sieve. This material separates the oxygen from the nitrogen and other gases.
  • Page 10 [Read the Important Safety Rules section before operating this equipment.] Operator Profile: AirSep’s Stationary Concentrators are intended to supply supplemental Oxygen to users suffering from discomfort due to ailments which affect the efficiency of ones lungs to transfer the oxygen in air to their bloodstream. Users can benefit from supplemental oxygen therapy for respiratory care at home, in the hospital, or at a medical facility.
  • Page 11 [Read the Important Safety Rules section before operating this equipment.] Concentrator Components Review the figures below and become familiar with the important parts of your VisionAire 2 or VisionAire 3 Oxygen Concentrator. Front of Concentrator Top Handle Oxygen Outlet Hour Meter...
  • Page 12 [Read the Important Safety Rules section before operating this equipment.] Ø Top and Side Handles: o Enables convenience in carrying the unit. Ø On/Off (I/0) Power Switch: o Starts and stops the operation of the unit. Ø Oxygen Outlet o Provides connection for a humidifier (if required) or cannula. Ø...
  • Page 13: Back Of Concentrator

    [Read the Important Safety Rules section before operating this equipment.] Back of Concentrator Humidifier Bottle Recess Power Cord Figure 2 Ø Power Cord: o Allows connection of the unit to an electrical outlet. Ø Humidifier Bottle Recess: o Area to place the optional humidifier bottle. MN165-1 Rev G...
  • Page 14: Humidifier Bottle

    Ø Humidifier Bottle Oxygen Outlet: o Connection for oxygen tubing/cannula. Accessories: Recommended for use with VisionAire 2 and VisionAire 3. The use of certain administration accessories which are not specified for use with this concentrator may reduce performance and void the manufacturer’s warranty.
  • Page 15: Materials In Direct Or Indirect Contact With The Patient

    [Read the Important Safety Rules section before operating this equipment.] 2.5 Materials in direct or indirect contact with the patient o Concentrator Cabinet (all parts) …………… NOVA PS6201 Super High Impact Polystyrene o Gas Outlet, Nozzle ………………………. Aluminum, Black Anodized o On / Off Switch ………………………..
  • Page 16: Humidifier Bottle Connection

    [Read the Important Safety Rules section before operating this equipment.] How To Operate Your Oxygen Concentrator Review the following information before you operate your oxygen concentrator. The concentrator releases warm air out the bottom of the unit which can permanently discolor temperature sensitive flooring surfaces such as vinyl. The concentrator should not be used over flooring that is sensitive to heat staining.
  • Page 17: Turning The Concentrator Off

    [Read the Important Safety Rules section before operating this equipment.] 1. Locate the unit near the electrical outlet in the room where you spend most of your time. 2. Insert the power cord plug into the electrical outlet. 3. Set the I/0 power switch to the “I” position to turn the unit on. An audible alarm will loudly sound for approximately 5 seconds.
  • Page 18: Humidifier Bottle

    Equipment Provider. Additional supplies are available from your Equipment Provider. To prevent a voided AirSep warranty, follow all manufacturers’ instructions. AirSep does not recommend the sterilization of this equipment. Humidifier Bottle (optional) •...
  • Page 19 [Read the Important Safety Rules section before operating this equipment.] Troubleshooting If your concentrator fails to operate properly, consult your Equipment Provider, and refer to the troubleshooting chart on the following pages for probable causes and solutions. Do not attempt any maintenance other than the possible solutions listed within the manual If the unit has not been used for an extended time period, it needs to operate for several minutes before power failure alarm can...
  • Page 20 [Read the Important Safety Rules section before operating this equipment.] Problem Probable Cause Solution Condensation Unit not properly Make sure unit is positioned away from collects in the ventilated. curtains or drapes, hot air registers or oxygen tubing Elevated operating heaters, Be certain to place the unit so all when you use temperatures.
  • Page 21 115 VAC / 60 Hz, 3.0 A Electrical Requirements 230 VAC / 50 Hz, 1.5 A 230 VAC/ 60 Hz, 1.5 A VisionAire 2 = 200 Watts (+/- 10%) Power Consumption VisionAire 3 = 175 Watts (+/- 10%) 40 dba Sound 14.1 in.
  • Page 22 [Read the Important Safety Rules section before operating this equipment.] “Specifications continued” Medical equipment needs special precautions regarding EMC and need to be installed and put into service according to the EMC information provided in this section. Guidance and manufacturer’s declaration ± electromagnetic immunity The unit is intended for use in the electromagnetic environment specified below.
  • Page 23 [Read the Important Safety Rules section before operating this equipment.] Guidance and manufacturer’s declaration ± electromagnetic immunity The unit is intended for use in the electromagnetic environment specified below. The customer or the user of the unit should assure that it is used in such an electromagnetic environment.
  • Page 24 [Read the Important Safety Rules section before operating this equipment.] Recommended separation distances between portable and mobile RF communications equipment and the Unit The unit is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the unit can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the unit as recommended below, according to the maximum output power of the communications equipment.
  • Page 25 Symbols can also permit easier comprehension of a concept within a restricted space. The following table is a list of symbols and definitions that may be used with AirSep’s VisionAire 2 and VisionAire 3 Oxygen Concentrators. These symbols are referenced...
  • Page 26 [Read the Important Safety Rules section before operating this equipment.] Method of disposing of waste: All waste from AirSep’s VisionAire 2 and VisionAire 3 Oxygen Concentrator must be disposed of using the appropriate methods. Method for disposing of the device: In order to preserve the environment, the concentrator must be disposed of using the appropriate methods.
  • Page 27: Section 8 Conformity With En

    Degree of safety of application in the presence of flammable gases: Equipment not suitable for such application. Mode of operation: Continuous duty. For European Representative: Gavin Ayling 9 Bungham Lane Penkridge Stafford Staffordshire ST19 5NH England E-mail: eurorepcontact@airsep.com MN165-1 Rev G...
  • Page 28 Manufactured by: AirSep Corporation Buffalo, NY 14228-2085 USA |MN165-1_GÆ~ MN165-1 Rev G...

This manual is also suitable for:

Visionaire 3