CONSTRUCTION AND DIMENSIONAL DIAGRAM

MODEL
RAF-35NX2
235
109
Piping hole
15
in left side
62
9 Rear fixing hole for
anchor bolt
More than 200mm
Cautions: 1. Use insulated pipes for both large and small diameters.
2. Use pipes of no more than 20m length.
3. Make sure the difference in heights between the indoor and outdoor units is 10m.
4. For built-in installation, make sure that the infrared receiver and indicator are not blocked.
5. Pipes can be laid out from the right, bottom or rear, when the unit is viewed from front.
6. Keep the clearance shown by
7. For built-in installation, keep the vertical deflector at top air outlet as flat as possible.
If it is inclined too much, heat will be trapped in the unit, which could cause faulty room temperature control.
8. An F-cable 1.6mm or 2.0mm dia. x 2 (control side) is used for the connection cable.
65 Standard underfloor piping position
Cabinet
Front panel
Air outlet
Air inlet
5 Hole for fixing to floor
60
115
More than 150mm
170
420
Drain hose
55
65 standard underfloor piping hole position
55
760
45
52
40
681
45
64
640
60
92
29
More than
More than
100mm
100mm
for installation.
– 32 –
Wireless remote
controller
56
Infrared receiver
Small dia. pipe
( 6.35)
Large dia. pipe
( 9.52)
Piping hole
in right side
Built-in installation
Lattice door
More than
200mm
Less than 20mm
Unit : mm
18
15
62
121