Set-Up; Power Supply - Hensel Integra Mini 300 User Manual

Compact flash
Table of Contents

Advertisement

User manual Integra Mini 300

Set-up

ATTENTION!
Please regard the general safety instructions reference set-up
location and surrounding area in the chapter „Set-up and initial
use" on page 5.
Compact flash units can be used regardless of tilting angle.
Please note that extremely angled positions can cause faster
heat built-up in the device, especially in connection with long,
tubular attachments. In severe cases, this can trigger the auto-
matic thermal switch-off function!

Power supply

ATTENTION!
Make sure that the power supply corresponds to the informati-
on on the labelling/ technical data sheet before connecting the
compact flash unit.
Compact flash units must only be connected to a grounded
power supply.
The type label is located at the bottom side of the housing. The
compact flash unit Integra Mini 300 is solely approved for use
with 115 V/230 V/ 50-60 Hz operation.
It features Multivoltage technology which means the unit auto-
matically adjusts to the applicable voltage.
Fuse protection, building
Power sockets intended for the connection of devices have to be
protected with a minimum of 10 A.
Fuse protection, modeling light
The safety fuse ensures the protection of the modeling light.
The compact flash unit Integra Mini 300 is protected by a 4 A
fuse which reacts quickly (F 4 A H).
The listed safety values are valid when the device is used with a
300 W halogen lamp.
(Please note „Replacing the fuses" on page 19).