4 | Product details
2
Product details
WBN 6000-30-H-E-N/L-S2400 are appliances for central heating.
2.1
Standard delivery
Fig. 1
[1]
Wall-mounted gas boiler
[2]
Fixing material
[3]
Set of printed documents for the appliance
[4]
Flue pipe
[5]
Grommet
[6]
Regulator( Only for NG appliance )
2.2
Overview of the gas categories that can be used
The code number indicates the gas family according to AS 4552:
Code
Wobbe index (W
number
(15 °C)
23
12.2 - 55.0 MJ/m
31
72.9 - 87.2 MJ/m
Table 2
1)
LPG type
Commercial Propane
Commercial Butane
General Product
Universal LPG (U-LPG)
Table 3
1) according to NZS 5435
2.3
Data plate
Fig. 2
8 716 473 216 (2014/09)
)
S
Gas type
3
NG
3
LPG
Use
recommended
permitted
permitted
permitted
8 716 473 216-02.3O
On the data plate, you will find details on the appliance output, approval
information and the series number.
2.4
Description of appliance
• Gas boiler only for external installation
• Gas boiler only for central heating
• Gas boiler for wall installation
1
• Power cable
• Liquid Crystal Display
2
• Automatic ignition
• Continuously controlled output
• Full backup via the electronics with flame monitoring and solenoid
3
valves according to EN 298
• Three-stage heating circuit pump with automatic air vent valve
4
• No minimum water circulation rate required
• Fixed connections for flue gas/combustion air as concentric pipe
Ø 60/100 mm
5
• Curve-controlled fan
• Temperature sensor and temperature control for central heating
• Temperature limiter in the flow
6
• Safety valve, pressure gauge, expansion vessel
2.5
Accessories
Below is a list of typical accessories for this appliance.
You can find comprehensive details of all available
accessories in our catalogue.
• Digital thermostat
Gaz 6000 W