14 | Electrical connections
Fixing the flue pipe
1. Fix the short flue pipe.
2. Fix the flue weather seal.
1.
1. 1.
2. 2.
2.
Fig. 14
6
Electrical connections
6.1
General notes
DANGER: Risk of electric shock
▶ Before carrying out work on electrical components,
disconnect the power supply (240 V AC) (fuse, circuit
breaker) and secure against unintentional
reconnection.
All appliance modulation, control and safety components are tested and
ready-wired for use.
Observe safety measures according to the relevant regulations and AS/
NZS 3000.No other electrical consumer units may be connected to the
same power cable.
Fuses
The appliance is protected by two fuses. They are located on the circuit
board.
Replacement fuses are located on the cover of the
control unit.
6.2
Connecting appliances with power cable and mains
plug
▶ Insert the power cable plug into an earthed power socket.
8 716 473 216 (2014/09)
6.3
Control unit terminals
Flipping down the control unit
1. Undo screws.
2. Pull the control unit down.
3. Flip the control unit down.
8 716 473 216-14.1O
Fig. 15
6.3.1 Connecting the on/off controller or Open Therm controller
Only operate this appliance with a controller.
The controller must be suitable for mains voltage (from boiler) and must
not have its own earth connection.
For installation and electrical connection, see the relevant installation
instructions.
The controller connection on the control unit is located underneath a
cover.
▶ Remove the cover.
▶ Remove the jumper from the TH terminals.
▶ Connect the controller to the TH terminals.
Fig. 16
NOTICE: Cable residues can damage the control unit.
▶ Only remove the insulation from the cable outside the
control unit.
The casing is secured with two screws against
unauthorised removal (electrical safety).
▶ Always secure the outer casing with these screws.
ok
reset
press 5s
mode
1.
1.
1.
3.
2.