Product Data On Energy Consumption - Bosch Worcester Greenstar CDi Classic System ErP Series Installation, Commissioning And Servicing Instructions

Wall hung rsf gas fired condensing system boiler
Table of Contents

Advertisement

2.4

Product data on energy consumption

The following product data satisfy the requirements of the EU Regulations No. 811/2013, No. 812/2013, No. 813/2013 and No. 814/2013
supplementing Directive 2010/30/EU.
Product data
Product type
Condensing boiler
Rated heat output
Seasonal space heating energy efficiency
Energy efficiency class
Useful heat output
At rated heat output and high temperature regime
At 30 % of rated heat output and low temperature regime
Useful efficiency
At rated heat output and high temperature regime
At 30 % of rated heat output and low temperature regime
Auxiliary electricity consumption
At full load
At part load
In standby mode
Other items
Standby heat loss
Emissions of nitrogen oxides
Sound power level, indoors
Table 9 Product data for energy consumption
1) High temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
2) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
6 720 815 724 (2015/11)
Symbol
Unit
7 738 100 244 7 738 100 233 7 738 100 236 7 738 100 237
30CDi Classic
System
P
kW
rated
%
s
1)
P
kW
4
2)
P
kW
1
1)
%
4
2)
%
1
el
kW
max
el
kW
min
P
kW
SB
P
kW
stby
NOx
mg/kWh
L
dB(A)
WA
30CDi Classic
35CDi Classic
ErP
ErP
System
LPG
Yes
Yes
30
30
92
92
A
A
30.0
30.0
10.0
10.0
88.2
88.2
97.5
97.5
0.058
0.058
0.030
0.030
0.004
0.004
0.048
0.048
30
30
55
55
APPLIANCE INFORMATION
35CDi Classic
ErP
ErP
System
System
LPG
Yes
Yes
34
34
92
92
A
A
34.0
34.0
11.4
11.4
88.2
88.2
97.5
97.5
0.058
0.058
0.030
0.030
0.004
0.004
0.048
0.048
30
30
58
58
9