4.9 Stopping the engine

Preconditions
☑ Engine is running in local mode.
CAUTION
Stopping the engine when it is running at full load causes extreme stress to the engine.
Risk of overheating, damage to components!
• Before shutting down, disengage gear and run the engine at idle speed for at least 10 mins. until
engine temperatures have dropped and constant values are displayed.
The engine can be stopped from the following points :
1.
(→ Operating instructions for electronic system)
2.
Commanding control stand (→ Operating instructions for electronic system);
3.
Local operating panel LOP (→ Operating instructions for electronic system);
4.
Local Operation Station LOS (→ Operating instructions for electronic system);
5.
CCU (→ Operating instructions for electronic system).
48 | Operation | MS150063/01E 2012-01