Connect Electricity

WARNING
Do not use an extension cord or an adapter plug with
this appliance.
The water heater must be electrically grounded in
accordance with local codes and ordinances or, in the
absence of local codes, in accordance with the
National Electrical Code, ANSI/NFPA No. 70.
Water heaters are equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or
remove the grounding terminal from this plug.
Do not rely on the gas or water piping to ground the
water heater. A screw is provided in the junction box
for the grounding connection.
The water heater requires 120 VAC, 60 Hz power from
a properly grounded circuit.
If using the 5 foot long power cord, plug it into a
standard 3 prong 120 VAC, 60 Hz properly grounded
wall outlet.
The wiring diagram is located on the Technical Sheet
attached to the inside of the front cover.
Adjust for High Altitude (or U.S.
installations)
The gas and power to the water heater should be
turned off. On the SW1 DIP switch (tan switches), set
switches 2 and 3 to the values shown in table below
for your altitude. The default setting for the
appliance is 0-2000 ft (0-610 m) with switches No. 2
and No. 3 in the OFF position.
When the DIP switch is adjusted, it is not necessary to
adjust the gas pressure setting for high altitude.
0-2000 ft (0-610 m)
2001-5200 ft (610-1585 m)
5201-7700 ft (1585-2347 m)
7701-10200 ft (2347-3109 m)
Adjust for High Altitude
610 - 1372 m (2001 - 4500 ft)
for Canada Only
The gas and power to the water heater should be
turned off. On the SW1 DIP switch (tan switches),
set switches 2 and 3 to the values shown in table
below for your altitude. The default setting for the
appliance is 0-2000 ft (0-610 m) with switches No. 2
and No. 3 in the OFF position.
When the DIP switch is adjusted, it is not necessary
to adjust the gas pressure setting for high altitude.
0-2000 ft (0-610 m)
2001-4500 ft (610-1372 m)
The conversion shall be carried out by a manufactur-
er's authorized representative, in accordance with the
requirements of the manufacturer, provincial or terri-
torial authorities having jurisdiction and in accord-
ance with the requirements of the CAN/CGA-B149.1
or CAN/CGA-B149.2 Installation Codes
UGT Series Manual
Altitude
Altitude
SW1
SW1
Switch
Switch
No. 2
No. 3
OFF
OFF
OFF
ON
ON
OFF
ON
ON
SW1
SW1
Switch
Switch
No. 2
No. 3
OFF
OFF
OFF
ON
19