Auto Mode set up
Once the auto changeover option has been selected, touch SAVE.
Enable or Disable: Choose to enable or disable auto changeover mode
S
Default = Enable
d
Auto changeover time: Adjustable from 5 to 120 minutes
S
Default = 30 minutes
d
6.3.1.2.
Heat/Cool Deadband
The minimum difference enforced between heating and cooling desired
temperatures. The deadband does not change when the user changes between
Fahrenheit (_F) and Celsius (_C). Ex: A 2_ deadband will be 2_F or 2_C and does
not change with units, _F and _C. This can allow one setting to "push" the other to
maintain this difference. When the correct deadband is set, touch SAVE.
Deadband: Adjustable from 0 to 6_ F
S
Default = 2_
d
6.3.1.3.
Offsets
This option allows calibration (or deliberate miscalibration) of the temperature and
humidity sensors. These offsets are added to the actual temperature/humidity
values. When the correct offsets are made, touch SAVE.
Outdoor temperature: Adjustable from - - 5 to 5_F (- - 3 to 3_C)
S
Default = 0_F
d
Humidity: Adjustable from - - 10 – 10%
S
Default = 0%
d