AV-21L41
Measuring
Item
instrument
Signal
Adjustment
generator
of DELAY
POINT
Remote
(AGC)
control unit
DELAY POINT
AGC TAKE-OVER
- / + : OPERATE
Setting Item
DELAY POINT
(AGC TAKE OVER)
20
Test point
Adjustment part
DELAY POINT
(AGC TAKE-OVER)
UHF
**
DISP : EXIT
Variable range
NTSC 3.58
0 ~ 127
OTHER
No. 51859
Description
1. Input a black and white signal (colour off).
2. Select 1. IF from the SERVICE MENU.
3. Select 2. DELAY POINT by pressing the 2 key on the remote
control unit.
4. Set the setting values of the setting items as shown bellow
tabbe.
5. Then adjust the MENU - or + key until video noise disappears.
6. Turn to other channels and make sure that there are no
irregularities.
Initial setting value
MU
48
43