Kenmore SEARS 625.34846 Owner's Manual page 20

Kenmore water system user manual
Table of Contents

Advertisement

SECTION 5
SERVlCER'S
TECH. I..ORMATION
5A.
TROUBLESHOOTING
AUTOMATIC ELECTRONIC DIAGNOSTICS
The face plate computer has a self-diagnostic
function for the electrical system (except input
power and water meter). The
Erlr"
I
computer monitors the electron-
D-_
ic components and circuits for
correct operation. If a malfunction occurs, an
error code appears in the face plate display.
The chart below shows the error codes that could
appear, and the possible defects for each code.
While an error code appears in the display, all
face plate buttons are inoperable except the
SELECT button. The SELECT button remains
operational so the service person can make the
MANUAL INITIATE ELECTRONIC
DIAGNOS-
TICS to further isolate the defect, and check the
water meter.
POSSIBLE DEFECT
CODE
MOST LIKELY
_
_
LESS LIKELY
Err 01
motor inop. / widncj hamass or connection to switch / position switch / face plate
Err 02
face plate
Err 03
motor inop. / face plate
Err 04
face plate / position switch
Err 05
face plate
PROCEDURE
FOR REMOVING ERROR CODE FROM FACE PLATE: 1. Unplug transformer 2. Correct defect
3. Plug-in transformer 4. Wait for 6 minutes. The error code will retum if the defect was not corrected.
MANUAL
INITIATED
ELECTRONICS
DIAG-
NOSTICS
1.
To enter diagnostics, press and hold the
SELECT button until (000 - -) shows in the
display.
_
MOTOR
PosmoN
""'
plnnn___"l
swn'c.
!1
i .._._td_'_....,.--.-'I'URB|NE
A. tionThe
asfirstfollows:3
digits indicate water meter opera-
_
S%P_AND
000 (steady)=
soft water not in use...no
VALVE
It_k_A)'
flow through the meter.
OUTLET----.--,_/
--OPEN A NEARBY SOFT WATER FAUCET-
000 to 199 (continual) = repeats display for
each gallon of water passing through the me-
ter.
B. The letter (P) and dash(as) indicate POSI-
TION switch operation. The letter appearing
means the switch is closed; the dash means
the switch is open.
Use the ON/OFF-HOLD
(Recharge Now)
button to manually advance the valve into
each cycle and check correct switch opera-
_on.
If you don't get a reading in the display, with
faucet open, pull the sensor from the valve
outlet porL Pass a small magnet back and
forth in front of the sensor. You should get a
reading in the display. Ifyou get a reading, un-
hook the in and out plumbing and check the
turbine for binding.