SECTION 5
SERVICE TECH INFORMATION
5A.
TROUBLESHOOTING
should
get
a reading
in the
display.
If you
get
a
reading,
unhook
the in and out plumbing
and check
the turbine
for binding.
o-"
POSITION
SWITCH
MOTOR
SENSOR
HOUSING
TURBINE
TURBINE
SHAFT
VALVE
VALVE POSITION
INDICATORS:
Depending
on
the
valve
position,
the following
indicators
show
in the
display:
INDICATOR
VALVE POSITION
Serv
.........
service
Fill ...........
fill
Brine .........
brining/brine
rinse
Bkwash
......
backwash
Rinse
........
fast rinse
When the valve is rotating from 1 cycle to another,
both indicators
flash. For example,
if the valve is in
transition
between
fill and brining,
both
Fill and
Brine flash. Upon reaching brining position, Fill goes
off and Brine is on steady. The time display shows the
minutes of the cycle remaining.
NOTE: If the face plate is left in a diagnostic display
(or
a flashing
display
when
setting
times
or]
hardness),
present
time automatically
returns
if a
button is not pressed within 4 minutes. To return to
the diagnositc display, repeat step 2.
OTHER INFORMATION. While in this diagnostic screen,
the
following information
is available and
may be
beneficial
for various
masons.
This information
is
retained by the computer from the first time electrical
power is applied to the face plate.
...Press
[]
to display the number of days this face
plate has3_ad electrical Power applied.
...Press
[_
to display the number of regenerations
initiated by this face plate since the HF code number
was entered.
23
3.
Press
the #1 SELECT button
and hold 3 seconds
until...
...SFaashows.
H; 2
This code identifies the softener nominal capacity size.
If the wrong number shows, the softener will operate
on
incorrect
programming.
Do the
following
as
needed.
HF32
does
show
--
Press the #1 SELECT button
to
return
the present
time display.
To
change
HF
number
-
Press
the
[]
or
[]
button
until
HF32
shows.
Then,
press
the
#1
SELECT button
and reset the timer...page
6.
FACE PLATE REPLACEMENT:
Be sure the valve
is in service
position
(observe
valve
cycle
indicator)
when
replacing
the face
plate.
If, after installing
and programming
the replace-
ment face place,
the valve
_
in service
posi-
tion,
do the
following
to assure
correct
cycle
orientation,
or timing,
between
the face plate
and valve.
Use the MANUAL ADVANCE
procedures,
page
24. With the RECHARGE
NOW button,
advance
through
the recharge
cycles
until the valve stops
in service
position,
and RECHARGE
no longer
flashes
in the timer.
NOTE: The valve motor may automatically
drive
through several valve positions while searching
for service. If an error code occurs, unplug the
transformer,
then plug in again.
11"10