SECTION 5
SERVICE TECH. INFORMATION
5A.
TROUBLESHOOTING
AUTOMATIC
ELECTRONIC
DIAGNOSTICS
The faceplate timer (PWA) computer
has a self-diag-
nostic function
for the electrical system, except
for
input
power
and
water
meter.
_,_
The computer
monitors the elec-
--,--
Err_
tronic
components
and
circuits
for correct
operation.
If a mal-
!
function
occurs,
an error
code
{
appears in the faceplate display.
- - - -
The chart below
shows the error codes that could
appear, and the possible defects for each code.
While an error code appears
in the display, all face
plate
buttons
are
inoperable
except
the
SELECT
button.
SELECT remains operational
so the service
person
can make the MANUAL INITIATED ELEC-
TRONIC DIAGNOSTICS (below) to further isolate the
defect, and check the water meter.
CODE
Err1
Err3
Err4
Err5
POSSIBLE DEFECT
MOST LIKELY
LESS LIKELY
motor inoperative / wiring harness or connection to switch / position switch / faceplate timer (PWA)
motor / faceplate timer (PWA)
See faceplate timer (PWA) replacement
timer (PWA) / position switch
on page 23.
i faceplate timer (PWA)
PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE: 1. Unplug transformer 2. Correct defect
3. Plug in transformer
4. Wait for 6 minutes. The error code will return if the defect was not corrected.
MANUAL
INITIATED
ELECTRONICS
DIAG-
NOSTICS
1. To enter diagnostics...
--from a error code display, press the #1 SELECT
button.
--from
a time
display,
press and hold the #1
SELECT button for 3 seconds.
You will see
1 of the following
displays.
All of the
displays
show
what
position
the valve
is in, if the
turbine
is operating,
and the position
switch
open
or
closed
status.
van _
_a_
---'--;:-.-I
posi_onswish ind_
VALVE iN SERVICE
POSITION
-
8 .28
lutt_c_e count
FosittonImttch indicalor
(o_n)
VALVEIN k RECHARGE
POSITION (FILL IN THIS
EXAMPLE)
(F¢araBrae _a_h_ng)
I
_
minu_s of bd_ng _e
I_.----t_ / _lJS"t_ (_=_"-.
_--_,
POSITION TO
i_..
water meW¢
ANOTHER (FROM
uxtx_e counl
RLL TO BPJNINQ IN
posi_nswitch indicator
THISEXAMPLE)
(eked)
2.
Press the ON/OFF-HOLD
button to advance the
valve to the next position. To verify component
operation,
or to possibly isolate a defect, observe
the following.
POSITION SWITCH STATUS: With the valve in service,
or any of the recharge cycles, the switch indicator will
show open
---_--. While the valve is rotating from 1
position to another, the indicator will show the switch
closed
--"_. A defect is probable
if indications
vary
from this pattern.
WATER METER TURBINE: With soft water in use, the
turbine flow rate display continually
repeats a 000 to
140 count for each gallon of water passing through the
turbine. The display will remain a steady...000
if soft
water is not in use (open a nearby soft water faucet to
check).
If you don't get a reading in the display, with faucet
open, pull the sensor from the valve outlet port. Pass a
small magnet back and forth in front of the sensor. You
22