Keep The Softener - Kenmore 625.3486 Owner's Manual

High flow deluxe demand water softener
Table of Contents

Advertisement

SECTION
3
cARE oFYour so
.ER
30.
KEEP THE SOFTENER
FROM FREEZING
If the
softener
is installed
where
it could
freeze
(summer
cabin, lake home,
etc.), you must
drain
all
water
from
it to stop
possible
freeze
damage.
To
drain
the softener
--
1.
Close
the
shut-off
valve
on the
house
main
water
pipe,
near
the water
meter
or pressure
tank.
.
°
°
Open a faucet
in the soft water
pipes
to vent
pressure
in the softener.
Refer to FIG. 12 on page
19. Move
the stem
in a
single
bypass
valve
to bypass.
Close
the inlet
and
outlet
valve
in a 3-valve
bypass
system,
and open
the bypass
valve.
If you want
water
in
the
house
pipes
again,
reopen
the
shut-off
valve
on the main
water
pipe.
Unplug
the
transformer
at the
wall
outlet.
Remove
the salt hole cover
and the main
cover.
Take off both
drain
hoses.
°
°
Carefully
remove
the large
holding
clips at the
softener
inlet
and
outlet
(see
Key
No.
69, on
page
30). Separate
the softener
from the copper
tubes,
or from
the bypass
valve.
Remove
the brinewell
cover and disconnect
the
brine
valve
tubing
at the
nozzle
and
venturi
assembly
(see page
30). Lift the brine
valve
out
of the
brinewell.
Tip
the brine
valve
upside
down
to drain
water.
°
°
DRAIN WATER FROM THE
SOFTENER
drain
wood block
Looking
at FIG. 11, lay a piece
of 2 inch
thick
board
near
the floor
drain.
Move
the softener
close
to the drain.
SLOWLY
and CAREFULLY,
tip it over until
the rim rests
on the wood
block
with the inlet and outlet
over
the drain.
Do not
allow
the softener's
weight
to rest on the inlet
and
outlet
fittings
or they
will
break.
Tip the bottom
of the softener
up a few inches
and hold until
all water
has drained.
Leave
the
softener
laying
like this until
you
are ready
to
use it. Plug
the
inlet
and
outlet
with
rags
to
keep
dirt, bugs,
etc. out.
17