Kenmore 625.3486 Owner's Manual page 23

High flow deluxe demand water softener
Table of Contents

Advertisement

SECTION 5
SERVICE
TECH
INFORMATION
5A.
TROUBLESHOOTING
MANUAL
ADVANCE
REGENERATION
CHECK
This check verifies
proper
operation
of the valve
motor,
brine
tank
fill, brine
draw,
regeneration
flow rates, and other controller
functions.
Always
make the initial
checks,
and the manual
initiated
diagnostics.
NOTES:
The faceplate
display
must
show
a steady
time
(not
flashing).
If an error
code
shows,
first
press
the SELECT
button
to enter
the
diagnostic
display.
1. Press the ON/OFF-HOLD
button
and hold in
for 3 seconds.
*RECHARGE
and Fill begin
to
flash (or clean backwash
begins,
if set) as the
softener
enters
the fill cycle of regeneration.
When FILL is on steady, remove
the brinewell
cover and, using a flashlight,
observe
fill water
entering
the tank.
*NOTE:
If the CLEAN
feature
is set to ON, a
cleaning
backwash
(CLEAN and Bkwsh or Rinse
flashes in the display,
along with the minutes
of the
clean cycle remaining),
precedes
the recharge.
a.
If water
does
not enter
the tank,
look for an ob-
structed
nozzle,
venturi,
fill flow
plug,
brine
tubing,
or brine
valve
riser
pipe.
CYCLE FLOW RATES (GALLONS PER MIN.)
FILL (flow to salt storage tank)
0.3 (1.1 liters)
BRINING
'_
.16 (.61 liters)
BRINE RINSE
I
.12 (.45 liters)
BACKWASH
(flow to drain) 1.8 (6.8 liters)
FAST RINSE
1.8 (6.8 liters)
2. After observing
fill, press the ON/OFF-HOLD
button
to move
the softener
into brining.
A
slow
flow of water
to the drain
will begin.
Verify
brine
draw
from
the
brine
tank
by
shining
a flashlight
into the
brinewell
and
observing
a noticeable
drop in the liquid level.
NOTE:
Be sure a salt bridge
is not preventing
water with salt contact.
at
If the softener
does
not draw
brine...
... nozzle
and/or
venturi
dirty
or defective.
...nozzle
and venturi
not seated
properly
on
gasket.
...restricted
drain
(check
drain
fitting
and
hose).
... defective
nozzle
and venturi
seal.
...other
inner
valve
defect
(rotor
seal, rotor
&
disc, wave
washer,
etc.).
23
NOTE:
If water
system
pressure
is low, an elevated
drain
hose
may
cause
back
pressure,
stopping
brine
draw.
3.
Again
press
ON/OFF-HOLD
to
move
the
softener
into backwash.
Look for a fast flow
of
water
from
the drain
hose.
at
t
t
An obstructed
flow indicates
a plugged
top dis-
tributor,
backwash
flow plug, or drain hose.
Press
ON/OFF-HOLD
to move
the
softener
into fast rinse.
Again
look for a fast drain
flow.
Allow
the softener
to rinse
for a few minutes
to
flush out any brine
that may remain
in the resin
tank
from
the brining
cycle test.
To return
the
softener
to service,
press
ON/
OFF-HOLD.
V__/Float
I Jz:q"-
stop
II
I.,....,_
Float
0,,
FREEBOARD MEASUREMENT
(Distance from top of resin tank, to top of resin bed.)
't
FREEBOARD
7"-11"
lr
resin tank
resin bed

Hide quick links: