Installations - Kenmore POWER MISER 153.339210 HA Owner's Manual

Kenmore water heater user manual
Table of Contents

Advertisement

Facts to Consider
About
the Location
Carefully choose an indoor location for the new water heater,
because the placement
is a very important
consideration
for
the
safety of the occupants
in the building and for the most
economical use of the appliance.
This water heater is not for
use in manufactured (mobile) homes or outdoor installation.
Whether replacing an old water heater or putting the water heater
in a new location, the following critical points must be observed:
Select a location
indoors as close as practical to the gas
vent or chimney to which the water heater vent is going to be
connected, and as centralized with the water piping system
as possible.
Selected
location
must provide adequate
clearances
for
servicing and proper operation of the water heater.
Property
Damage
Hazard
• AIIwater heaters eventually leak
• Do not install without adequate drainage
Installation of the water heater must be accomplished
in such a
manner that if the tank or any connections should leak, the flow
will not cause damage to the structure.
For this reason, it is not
advisable to install the water heater in an attic or upper floor.
When such locations cannot be avoided, a suitable drain pan
should be installed
under the water heater.
Drain pans are
available at your local hardware store.
Such a drain pan must
have a minimum length and width of at least 2 inches (51 mm)
greater that the water heater dimensions and must be piped to
an adequate drain.
The pan must not restrict combustion
air
flow.
Fire or ExpJosion
Hazard
heater's pilot light or main burner.
The resulting flashback and
fire can cause death or serious burns to anyone in the area.
Even though this water heater is a flammable vapors ignition
resistant water heater and is designed to reduce the chances
of flammable
vapors
being
ignited,
gasoline
and other
flammable substances
should never be stored or used in the
same vicinity or area containing
a gas water heater or other
open flame or spark producing appliance.
Also, the water heater must be located and/or protected so it is
not subject to physical damage by a moving vehicle.
Fire Hazard
For continued protection against
risk of fire:
,Do not instalJ water heater on
carpeted flooc
.Do not operate water heater if
flood damaged.
This water heater must not be installed directly on carpeting.
Carpeting must be protected by metal or wood panel beneath
the appliance extending beyond the full width and depth of the
appliance by at least 3 inches (76.2mm) in any direction, or if
the appliance is installed in an alcove or closet, the entire floor
must be covered by the panel. Failure to heed this warning may
result in a fire hazard.
Fire or Explosion
Hazard
using or servicing water heater.
• Improper use may result in fire or
explosion
• Maintan
required
clearances
to
combustibles.
" Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
app))ance
Avod
all ignition sources if you smell LP gas.
* Do not expose water heater controi to excessive gas
pressure
.
Use only gas shown on rating pJate.
.
Maintain
required
clearances
to combustibles
.
Keep ignition sources away from faucets after
,. extended period of non use
Read instruction manual before
_
installing, using or servicing
._,d(
_'
water heater
INSTALLATIONS
IN AREAS WHERE FLAMMABLE
LIQUIDS
(VAPORS)
ARE
LIKELY
TO BE PRESENT
OR STORED
(GARAGES,
STORAGE
AND
UTILITY
AREAS,
ETC.):
Flammable liquids (such as gasoline, solvents, propane [LP or
butane, etc.] and other substances
such as adhesives,
etc.)
emit flammable
vapors which can be ignited by a gas water
Minimum clearances between the water heater and combustible
construction
are 0 inch at the sides and rear, 4 inches
(102 mm) at the front, and 6 inches (153 ram) from the vent
pipe, see Figure 8. Clearance from the top of the jacket is 12
inches (305 mm) on most models. Note that a lesser dimension
may be allowed on some models, refer to the label attached
adjacent to the gas control valve on the water heater.
TOP ViEW
TOP VIEW
OF CLOSET
OF CLOSET
WITHOUT DOOR
WITH DOOR
(}" MIN
O" MIN.
O" I_IN,
4" MIN,
S" MIN,
FIGURE8.
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents