Filling The Water Heater - Kenmore POWER MISER 153.339210 HA Owner's Manual

Kenmore water heater user manual
Table of Contents

Advertisement

V!'_|7_[_.]_
_._ Water
temperature
over
125°F
(52°C) can cause severe burns
instantly resulting in severe injury
or death.
I
ChiJdren,
the
elderly,
and
the
,_,(_)
I
physically
or mentally
disabled
,''_J_f_'
I
areathighestrJskforscald
injury
'---_
_
F_el,Te_a_r
before
bathing
or
f
(/
_._
_
Temperature
limiting valves are
"%
"--_
"_--J_l R_,.,
available
_-_
Read instruction
manual for safe
-,.
,ternPerature setting:
The temperature-pressure
relief
valve must be manually
operated
at least once a year.
Caution should be taken to
ensure that (1) no one is in front of or around the outlet of the
temperature-pressure
relief valve discharge line, and (2) the
water manually discharged
will not cause any bodily injury or
property damage because the water may be extremely hot.
If after manually operating the valve, it fails to completely reset
and continues
to release water, immediately
close the cold
water inlet to the water heater, follow the draining instructions,
and replace the temperature-pressure
relief valve with a new
one.
HOT
'.'MATER
OUTLET
COLD
WATER
SHUTOFE
VALVE
TEMPERATURE
PR=SSURE
RELIEF VALVE
(OPTIONAL TOP T&P RELIEF
DRAFT
HOOD
VALVE NOT SHOWN)
_J_
_
DI£_HAR_IE:
PIPE
[DO NOT
CAp
OR PLUG)
_f_
DRAIN VALVE
Never use this water heater unless it is completely full of water.
To prevent damage to the tank, the tank must be filled with
water. Water must flow from the hot water faucet before turning
"ON" gas to the water heater.
To fill the water heater with water:
• Close the water heater drain valve by turning the handle to
the right (clockwise). The drain valve is on the lower front of
the water heater.
• Open the cold water
supply valve to the water
heater.
NOTE: The cold water supply valve must be left open when
the water heater is in use.
To insure complete filling of the tank, allow air to exit by
opening the nearest hot water faucet.
Allow water to run
until a constant flow is obtained.
This will let air out of the
water heater and the piping.
• Check all water piping and connections
for leaks.
Repair
as needed.
Venting
Breathing
Hazard
- Carbon
Monox{de
Gas
• Vent dampers
must be eertfied
in accordance with ANSI Z21 68
• Vent damper must permit proper
drafting of water heater.
• Install properly sized venting.
• Do
not
install
without
venting
outdoors.
• Do not install without draftflood.
• If
common
vented
install
in
accordance with NFPA 54
• Be a/eft for obstructed or deterio-
rated
vent
system
to
avoid
serious injuly or death
Breathing carbon mono×ide can cause brain damage or
death
Always read and understand nstruction manual
VENT DAMPERS
- Any vent damper, whether
it is operated
thermally or otherwise must be removed if its use inhibits proper
drafting of the water heater.
FIGURE16.
Filling the Water Heater
Property
Damage
Hazard
. Avoid water heater damage
. Fill tank with water before operating
Thermally
Operated
Vent Dampers: Gas-fired water heaters
having thermal efficiency
in excess of 80% may produce a
relatively low flue gas temperature.
Such temperatures
may
not be high enough to properly open thermally
operated vent
dampers.
This would cause spillage of the flue gases and
may cause carbon monoxide poisoning.
14
Vent dampers must bear evidence of certification as complying
with the current edition of the American
National
Standard
ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically
and mechanically actuated vent dampers).
Before installation
of any vent damper, consult your local Sears Service Center or
the local gas supplier for further information.