Imtallation Checklist - Kenmore POWER MISER 153.336151 Owner's Manual

Kenmore water heater user manual
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Installation
Checklist
BEFORE
LIGHTING
THE PILOT:
• Check the gaslines forleaks.
a. Use a soapy water solution• DO NOT test for gas leaks
usinga match or open flame.
b. Brush the soapy water solution on all gas pipes, joints and
fittings.
c. Check for bubbling soap• This means you have a leak.
Turn OFF gasandmake the necessaryrepairs.
d. Recheckfor leaks.
e. Rinseoffsoapy solution and wipe dry.
• Is the new temperature-pressure
relief valve properly installed
and piped to an adequate drain? See "Temperature-Pressure
Relief Valve" sexxiott.
VENT
PIPE TO
OUTDOORS
OR CHIMNEY
SHUTOFF VALVE
COLD
UNION
• Are the cold and hot water lines connected to the water
heater correctly? See _Water Piping" instructions in the
¢*
.
.
s_
.
Installation Instrucuons section.
• Is the water heater completely filledwith water? See "Filling"
instructions in the "Installation Instructions" section.
• Will a water leak damageanything? See the "Facts to
Consider About the Location section.
• Is there proper clearance between the water heater and any-
thing that might catch fire. See the Factsto Consider About
the Location section.
SH
GAS SUPPLY
DRAFT HOOD
• Do you have adequate ventilation so that the water heater
_
*c
....
.
will operateproperly. See Combustion Air and VentilaDon
in the _Installation Instructions" section.
• Is the drafthood vent piping properly secured? See _Venting"
instructions in the "Installation Instructions" section.
DRAIN
VALVE
• Is there proper dearancebetween the vent pipe and anything
that might catch on fire? See _Venting_ instructions in the
"Instalhtion Instructions" section.
PRESSURE
RELIEF VALVE
• Is the vent pipe properlysloped and does the vent terminate
outdoors? See "Venting instructions in the Installation
Instructions" section.
Do you need to call your gas company to check the gas pipe
arid its hookup?" section,
(Do not r.ap or plug)
6" AIR GAP
FLOOR
DRAIN
MODEL
RATING
PLATE
16