LG LP070CEM Service Manual page 43

Lg packaged terminal air conditioner/heat pump
Table of Contents

Advertisement

Heating Change of Temperature - Heat Pumps
Room Air
Room Air
LP070HM*
Dry
Wet
Temperature Across
Bulb
Bulb
Indoor Coil (∆ T)
Min
Rating Btu/h 6200
Rating CFM
220
85
22
80
23
50
75
24
70
26
65
26
85
19
80
20
45
75
21
70
22
65
23
85
17
80
18
40
75
19
70
20
65
21
85
15
80
16
35
75
17
70
18
65
19
Cooling Ampere Chart - Air Conditioners
Cond Inlet Air
Model
Temperature
LP070CM
Amperage
Min
Rating Ampere
2.6
100
2.6
95
2.4
90
2.3
85
2.2
80
2.1
Cooling Ampere Chart - Heat Pumps
Cond Inlet Air
Model
Temperature
LP070HM*
Amperage
Min
Max
Rating Ampere
2
.6
2.9
100
2.6
2.9
95
2.4
2.8
90
2.3
2.6
85
2.1
2.5
80
2.1
2.3
LP090HM*
Temperature Across
Indoor Coil (∆ T)
Max
Min
6400
8200
250
260
24
24
24
25
25
26
27
28
27
28
22
22
23
23
24
24
24
24
25
25
20
20
21
21
22
22
23
23
24
24
17
17
18
18
19
19
20
20
21
21
Model
LP090CM
Amperage
Max
Min Max
2.9
3.6
3.9
2.9
3.4
4.0
2.8
3.2
3.8
2.7
3.1
3.6
2.6
2.9
3.4
2.4
2.8
3.3
Model
LP090HM*
Amperage
Min Max
3.6
3.9
3.4
4.0
3.2
3.8
3.1
3.6
3.1
3.4
2.9
3.3
Model
LP120HM*
Temperature Across
Indoor Coil (∆ T)
Max
Min
8400
10900
290
330
27
27
28
28
29
29
30
31
30
31
24
24
25
25
26
26
27
27
28
28
22
23
23
23
24
24
24
25
25
26
20
21
21
22
22
23
23
23
24
24
Model
LP120CM
Amperage
Min Max
4.8
5.2
5.6
5.6
5.4
5.3
5.2
5.1
4.9
4.8
4.7
4.6
Model
LP120HM*
Amperage
Min Max
4.8
5.6
5.3
5.0
4.8
4.6
—43—
LP150HM*
Temperature Across
Indoor Coil (∆ T)
Max
Min
Max
11200
13300
13500
360
350
30
28
31
29
32
30
34
32
34
32
29
27
29
28
30
29
31
30
32
31
27
27
28
28
29
29
29
30
30
31
24
27
25
28
26
29
27
30
28
31
Model
LP150CM
Amperage
Min
Max
6.5
7.1
6.6
8.0
6.2
7.6
5.9
7.2
5.6
6.8
5.3
6.4
Model
LP150HM*
Amperage
Min
5.2
6.5
5.5
6.6
5.2
6.2
5.0
5.9
4.7
5.6
4.5
5.3
390
30
31
31
33
33
30
31
31
32
33
30
31
31
32
33
29
30
31
31
32
Max
7.1
8.0
7.6
7.2
6.8
6.4

Hide quick links: