LG LP070CEM Service Manual page 31

Lg packaged terminal air conditioner/heat pump
Table of Contents

Advertisement

Leveling Leg Assembly
To install the leveling leg assembly, complete the following:
1. Drill two 1/8-inch holes in each side of the wall sleeve, as
shown in Figure 43, using the leveling leg assembly as a
template. Locations near the front of the sleeve provide
more support.
2. Adjust the leveling legs to the approximate height needed
and install them on either side of the wall sleeve, using the
screws provided. Bottom of wall sleeve can be anywhere
from three to five inches above the screw base. Caulk
around screws to prevent water leaks.
3. Level the sleeve horizontally from side-to-side. Provide a
slight slope (one-quarter bubble in the sight glass) toward
the outside. Check the level again after the unit has been
installed. Adjust the legs as needed.
Figure 43 - Leveling Leg Assembly
Speed Grip Nut
Adjuster Screw
NOTES:
1. Two leveling legs are supplied in each kit.
2. One kit is required per unit.
3. Fout mounting screws are provided in each kit.
Leveler Bracket
1/2"
1"
1/4"
Installation on Wall Sleeve
1. Drill four 1/8-inch diameter holes in the wall sleeve, two on
each side, using the leveling legs as a template. Caulk
around screws to prevent water leaks.
2. Attach the legs to the wall sleeve, using the screws
provided.
3. Adjust the leveling legs to level the wall sleeve from side to
side and provide a slight pitch to the outside (one-quarter
bubble in sight glass).
Figure 44 - Leveling Leg Installation on Wall Sleeve
(four required per unit field-drilled)