Step
7
Remove evaporator
Turn over rear case and remove connection
1
screws between connecting pipe clamp and
rear case. Loosen clasps between connecting
pipe clamp and rear case. Then remove
connecting pipe clamp.
2
Loosen connection screws among evaporator,
motor clamp and rear case. Loosen clasps
between evaporator and rear case. Slightly
adjust pipeline. Then remove evaporator.
8.
Remove cross flow fan blade and motor
Remove 4 connection screws between
1
motor clamp and rear case. Then remove
motor clamp.
Procedure
pipe clamp
evaporator
motor clamp
assy