STEP 3: INSTALL FAUCET (cont.)-
B. ASSEMBLE
FAUCET
NOTE:
If the faucet
and spout
are unassembled,
slide
the spout into the faucet body.
1. Snap LED assembly
into electronics
ring (may
al-
ready
be assembled)
and o-ring
in the groove
on the
bottom
of the ring and slide the chrome
monitor
ring
onto the faucet
stud. The monitor
ring LED wire must
be routed
through
the sink or countertop
hole
and
through
the spacel; if spacer is used, (Figure
6).
NOTE: If you route the RO drain
tubing
directly
to the
drain
point, disregard
steps 2 and 4 below
and follow
directions
on page 17.
2. Take the 30" length of 3 / 8" black tubing and push one
end onto the 3/8" faucet barb fitting
(Figure
6).
3. Move the RO system
into position,
under
the sink.
(Referring
to page 7, hang
the system
on cabinet
wall,
or lay on the floor surface,
as desired.)
4. Route
the
1/4"
red tubing
fronl
the bottom,
up
through
the faucet mounting
hole. Push the end of the
tubing
onto the 1/4" faucet barb fitting.
5. Work
tubing
and
the faucet
stud
down,
into the
mounting
hole.
6. On the underside
of the sink or countertop,
slide the
spacel;
washer
and hex nut
on the faucet
stud.
The
spacer
can be flipped
depending
on the countertop
thickness.
Make sure that the LED wire is in a position
so that it will not be cut, pinched
or kinked
before tight-
ening the faucet assembly.
Tighten the hex nut securely.
7. Connect
the 1/ 4" blue tubing
&om faucet to the 3 / 8"
blue tubing
from the RO using
the 1/4"
x 3/8"
quick
connector
(Figure
6).
Note: See tubing connection
procedures
on page 14. For
ease of service
and maintenance,
keep tubing
lengths
long enough
so removal
of the RO system
from under
the sink is possible.
spacer ----.._ _
washer---_.._
hex nub---_
1/4" red tubing
from RO drain
(connect to 1/4"
barb on faucet)
3/8" blue tubing
(connect to faucet.
tubing)
1/4" x 3/8"
quick connect
3/8" black tubing
to
drain point (connect to
3/8" barb on faucet)
/
Figure 6
STEP 4: INSTALL RO ASSEMBLY -
Hang the assembly
on the included
hanger
washers,
or
lay on the cabinet
flool; as desired.
1. Refer to Figure
7 for wall mounting.
Hold the assem-
bly up to the wall
surface
and mark
locations
for the
hanger
washers.
Distance
needed
is 7.2"
(approx.
7-7/32")
apart.
2. Install
hanger
washers
at least 15-1/2"
up from the
cabinet
flool; allowing
room to remove
sumps
from fit-
ter heads.
Wood screws
are provided,
or obtain
other
fasteners
as needed.
3. Connect
telephone
style wire to the receptacle
on the
electronics
board,
located
on the top of the RO unit.
Route
the wire through
the strain
relief notch
on the
side of the manifold.
hanger
washer (2)
screw
15-1/2" min.
up from floor
Figure 7
7
Problems, Questions?
Call 1-800-426-9345
Kenmore Water Line