INSTALLING THE TELESCOPIC FLUE

Refer to figure 36.
1. Set the flue length to the distance required, secure
with screws provided.
2. Seal the joint with the aluminium tape provided.
3. Slide the inner wall seal onto the terminal.
4. If fitting from inside the building; slide the outer wall
seal onto the terminal.
2.
1.
Fig. 36 Telescopic flue
The turret securing screws are from the
boiler and are not in flue kit.
Refer to figures 37 & 38.
1. Remove the three inner flue tube retaining screws (2).
The inner tube will be held in place in the appliance.
2. Check the boiler flue seal is correctly seated and
apply silicone grease.
3. Position terminal through the flue opening in the wall
to the outside of the building by the distance shown.
4. Align the flue turret to the boiler flue outlet with flat
facing (1) to the rear of the boiler.
The flue turret should be pushed straight down, on to
the boiler.
1
Fig. 37
B Fit the screws removed in step 1 to secure flue turret.
6 720 644 741a (2010/10)
3.
TOP
1.
4.
6720644842-08.1Wo
2
6720643895-35.1Wo
B If fitting the outer seal from outside the building, slide
the outer wall seal onto the terminal as shown.
1.
1.
4.
2.
Fig. 38 Telescopic flue installation
For more information refer to the 60/100
Horizontal Flue kit Instruction Manual
ADDITIONAL NOTES AND REMINDERS:
• Ensure that all cut lengths are square and free from
burrs.
• The flue is sealed when assembled correctly and the
components are pushed fully home.
• The flue is set at an angle of 3° or 52mm per metre
length.
2m
1m
52mm
Fig. 39 Slope for condensate disposal