CONNECT LAUNDRY CENTER
TO GAS LINE
STEP 1. Remove the red cap from
the gas pipe. Move the laundry center
to its final position,
STEP 2. Connect gas supply to laundry
center. Use a wrench to tighten, For
gas connections you must use pipe joint
compound
resistant to the action of
L.P. gas. Apply
pipe joint compound
to the non-flared male threads
only.
There should be a natural loop in the
flexible gas connector, The flexible gas
connector must not be twisted, kinked
or attached with any sharp bends.
STEP 3. Open the shut-off valve in the
supply line. The valve is open when the
handle is parallel to the gas pipe.
STEP 4. Test all the connections
by
brushing on a soapy water solution
(liquid detergent also works well).
Bubbles will show a leak, Correct
any leak found, Never test for gas
leaks with a flame.
CORRECT
tl.
WRONG
Y
WRONG
o
27