Specification of the Ecostream cast iron boilers Logano GE315

Boiler size
Rated output
Application range for heat
demand
Rated heat input
1)
Net weight
Water capacity (approximate)
Gas content
2)
Flue gas temperature
Required draught
Pressure drop on hot gas side
3)
Permissible flow temperature
Permissible operating pressure
Certificate no. acc. to Pressure
Equipment Directive
CE designation
Tab. 3 Specification of the Ecostream cast iron boilers and Ecostream cast iron boiler units Logano GE315
(dimensions
1) Add the weight of the burner to the weight of the valve; weight incl. packaging is approx. 6 % to 8 % higher
2) To EN 303; minimum flue gas temperature for chimney calculation to DIN-EN 13384-1 (
3) Safety limit (high limit safety cut-out); maximum flow temperature 18 K lower than safety limit (STB)
Example: safety limit (STB) = 100 °C, maximum flow temperature = 100–18 = 82 °C
2.3.4
Specification of the Logano GE515 cast iron boilers
Boiler size
Rated output
Application range for heat
demand
Rated heat input
1)
Net weight
Water capacity (approximate)
Gas content
2)
Flue gas temperature
Required draught
Pressure drop on hot gas side
3)
Permissible flow temperature
Permissible operating pressure
Certificate no. acc. to Pressure
Equipment Directive
CE designation
Tab. 4 Specification of the Ecostream cast iron boilers and Ecostream cast iron boiler units Logano GE515
(dimensions
1) Add the weight of the burner to the weight of the valve; weight incl. packaging is approx. 6 % to 8 % higher
2) Figures acc. to EN 303; minimum flue gas temperature for chimney calculation to DIN-EN 13384-1 (
3) Safety limit (high limit safety cut-out); maximum flow temperature 18 K lower than safety limit (STB)
Example: safety limit (STB) = 100 °C, maximum flow temperature = 100–18 = 82 °C
6 720 646 864 (12/2010) – Technical guide Logano GE315, GE515 and GE615
Unit
GE315
kW
GE315
kW
GE315
kW
kg
l
l
Partial load
°C
60 %
°C
Full load
Pa
GE315
mbar
°C
bar
Fig. 6 and Tab. 1)
Unit
GE515
kW
GE515
kW
GE515
kW
215.6–259.7 257.8–319.0 316.6–377.1 374.6–429.6 428.4–489.2 488.2–547.8
kg
l
l
Partial load
°C
60 %
°C
Full load
Pa
GE515
mbar
°C
bar
Fig. 7 and Tab. 2)
105
140
105
140
86–105
106–140
92.1–113.5
113.5–151.4
543
631
143
171
147
181
137
138
162–185
154–182
0.28–0.41
0.46–0.79
Z-FDK-HUC-00-318-302-02
240
295
240
295
201–240
241–295
296–350
1270
1430
258
294
421
487
138
138
164–183
161–183
161–177
0.5–0.6
1.0–1.4
Z-FDK-HUC-00-318-302-04
Technical description
170
200
170
200
141–170
171–200
151.0–183.4
183.1–215.1
719
807
199
227
215
249
136
132
161–180
158–176
0
0.71–1.30
1.34–1.78
120
6
CE-461 AS 255
Tab. 42) (approx. 12 K lower)
350
400
350
400
351–400
401–455
1590
1753
330
366
551
616
140
129
157–171
159–172
0
1.1–1.6
2.1–2.9
2.5–3.3
120
6
CE-0461 AR 6154
Tab. 43) (approx. 12 K lower)
2
230
230
201–230
215.2–247.9
895
255
263
141
168–190
1.32–1.77
455
510
455
510
456–510
1900
2060
402
438
681
745
130
140
164–174
2.4–3.1